Ariterm GSM A2 Installation And Operating Instrictions Download Page 2

 ARITERM GSM A2

ARITERM SWEDEN AB

 

  

Installation instructions - 

2011.11.24 - Page 2/8

  Introduction

Ariterm GSM-A2 is a compact universal alarm transmitter that transmits alarms 
and receives commands via SMS. The alarm and status changes appear as
explanatory text depending on which pre-programming one selects.
The alarm goes to the telephone number that initiates A2.  
One can then add more numbers via SMS.
GSM-A2 is designed for GSM technology and requires a valid SIM card. 
Works with operators in the 2G network and higher.  
Both pay-as-you-go and subscriptions can be used.

  Connection / Quick start

1.   Connect the burner or stove according to the diagrams on the following 

pages. If one connects a burner or stove with control CC05 it must  
be connected according to image A and B. The Remote function must  
be activated in the controller Service menu (See manual).

2.   Carefully slide the SIM card into the A2’s upper edge with the chip 

towards you and the bevel down to the left. Image C.

3.   Connect 9208 AC -DC adapter 24Vdc to a wall socket. When the voltage 

supply is connected the “Status” flashes quickly for 30-40 seconds, then 
1-5 slow flashes. The flashes displays the GSM network signal strength.

4.   Initiate the unit by SMSing 

Ariterm!!

 or 

Ariterm!!01

 depending on the 

connection used. Note that the number used for initiation is the first  
number receiving alarms. Check the unit by SMSing 

Status?

5.   Add more numbers that receive alarms by SMSing 

TELE!*2 

followed by 

the mobile number that will receive alarms. 
Country prefix (eg +46 for Sweden) replaces the first zero in the  
telephone number.

 

Such as 

TELE!*2 +4670123456

 

 

 

TELE!*3 +4671234567

 

 

 

and so on.

 

Image A

Summary of Contents for GSM A2

Page 1: ...INSTALLATION and OPERATING INSTRUCTIONS ARITERM GSM A2 ...

Page 2: ...ol CC05 it must be connected according to image A and B The Remote function must be activated in the controller Service menu See manual 2 Carefully slide the SIM card into the A2 s upper edge with the chip towards you and the bevel down to the left Image C 3 Connect 9208 AC DC adapter 24Vdc to a wall socket When the voltage supply is connected the Status flashes quickly for 30 40 seconds then 1 5 ...

Page 3: ...RITERM SWEDEN AB Installation instructions 2011 11 24 Page 3 8 Image B Image C 2 Grey Grey Brown Black Red Red Black Brown 1350 Capacitive sensor EC1808 Brown Black Blue 5292 Tank sensor Ing4 5358 Smoke gas sensor Ing2 ...

Page 4: ...anges Alarm relay from the burner to the stove grey brown When the burner or stove is started SMS Started1 Msg100 is sent When the burner or stove is stopped SMS Stopped1 Msg101 is sent When the burner or stove stops during operational stoppage SMS Alarm1 Msg102 is sent Input 2 Ing2 COM Alarm or status changes Alarm relay from the burner to the stove grey brown When the burner or stove is started ...

Page 5: ... limit Tmp4 Factory setting 50 setting range 10 90 Sends SMS TempAlarm Msg108 if the temperature has fallen below the temperature limit Tmp4 for more than 5 mins At first start The function is deactivated until the temperature rises above the temperature limit To modify the temperature limit Send Temp As a response you get Temp 1 053 2 240 3 053 4 050 5 053 Example We wish to change the temperatur...

Page 6: ... 5 s Activate relay REL 1 5 s GSM Ariterm initiation ok Return SMS with Status Response Return SMS with all entered numbers Return SMS with temp With CC05 an ack nowledgement is obtained via Ing1 GSM Ariterm initiation ok Return SMS with all entered numbers Return SMS with all entered numbers Return SMS with voltage With CC05 an ack nowledgement is obtained via Ing1 With CC05 an ack nowledgement i...

Page 7: ...it 1 started Unit 1 gives alarm for operational stoppage Information about type of operational stoppage is read off on unit display The unit alarms for too low level in pellets store Unit 2 started Unit 2 gives alarm for operational stoppage Received after initiation Unit stopped via button or Remote Comments Smoke gas temperature has exceeded set value for more than 10 min Boiler temperature has ...

Page 8: ...tion operation and maintenance Ariterm Sweden AB s applicable warranties are not binding Ariterm reserves the right to make changes to components and specifications without prior notice Ariterm Sweden AB Flottiljvägen 15 SE 392 41 Kalmar www ariterm se ...

Reviews: