8
TECHNICAL SPECIFICATIONS / BOILER CROSS-SEC
TION
TECHNICAL SPECIFICATIONS
Performance values:
Power
20 - 40 kW
Measurement data:
Width
Depth
Height
Weight empty
Water capacity
Storage chamber volume
Burning time
Size of refill opening
Chimney recommendation
800 mm
1109 mm
1300 mm
690 kg
150 L
120 L
37 kg / 3 h
550x350 mm
150 mm, 4 m
Design and adjustment values:
Boiler operating pressure
Permitted operating temperature
Suitable size of accumulator
Max. length of logs
0,5-1,5 bar
Max 120 °C
1800 – 3000 L
0,5 m
afterburning
chamber
convection
section
storage chamber
grate
direct damper