Attention:
Attention:
Attention:
Attention:
Attention:
Several beeps indicate that you have done the wrong
keystrokes or actions.
P
P
P
P
P
ROGRAM
ROGRAM
ROGRAM
ROGRAM
ROGRAM
MODE
MODE
MODE
MODE
MODE
1.
1.
1.
1.
1.
Enter the Engineering code.
Press the ”#” button.
2.
2.
2.
2.
2.
Type ”0”.
3.
3.
3.
3.
3.
Enter a user number, which
must be a two-digit number
between 01 and 99 (for
example, user code 2 is
“02”).
4.
4.
4.
4.
4.
Hold an ACT700 card or an
ACT730 keyfob in front of
the slave reader ACL700.
5.
5.
5.
5.
5.
To program the next card or
keyfob, repeat steps 2 to 4.
6.
6.
6.
6.
6.
To leave the program, press
the ”#” button.
P
P
P
P
P
ROGRAMMING
ROGRAMMING
ROGRAMMING
ROGRAMMING
ROGRAMMING
A
A
A
A
A
PIN
PIN
PIN
PIN
PIN
CODE
CODE
CODE
CODE
CODE
A short beep sounds.
A short beep sounds after every
keystroke.
Two short beeps sound to confirm
that the user code has been
accepted.
A short beep sounds and the yellow
LED goes out.
The yellow LED lights up and a long
beep sounds.
A short beep sounds.
A short beep sounds after every
keystroke.
Two short beeps sound on the
keypad and on the reader. The card
or keyfob is accepted.
A short beep sounds and the yellow
LED goes out.
Example
Example
Example
Example
Example
of programming a user code in memory position 01
and user code 9874:
Type: ”Engineering code” # 0 01 9874
K
#
1.
1.
1.
1.
1.
Enter the Engineering code.
Press the ”#” button.
2.
2.
2.
2.
2.
Type ”3”.
3.
3.
3.
3.
3.
Enter the user number,
which must be a two-digit
number between 01 and 99
(for example, user code 2 is
“02”).
4.
4.
4.
4.
4.
Assign the relay or relays to
the user code or card.
Press ”1” if relay output
1 needs to be active.
Press ”2” if relay output
2 needs to be active.
Press ”12” if both relay
outputs 1 and 2 should
be active.
5.
5.
5.
5.
5.
Press the ”
K
” button.
6.
6.
6.
6.
6.
Continue programming the
relay mode or leave the #”
button.
P
P
P
P
P
ROGRAMMING
ROGRAMMING
ROGRAMMING
ROGRAMMING
ROGRAMMING
RELA
RELA
RELA
RELA
RELAY
Y
Y
Y
Y
ACTIONS
ACTIONS
ACTIONS
ACTIONS
ACTIONS
Both relays can be programmed in pulse or On/Off mode (the mode is
related to the relay and not per user.) One or two relays can be
assigned to every user code, card or keyfob.
The yellow LED lights up and a long
beep sounds.
A short beep sounds.
A short beep sounds after every
keystroke.
Two short beeps sound.
A short beep sounds and the yellow
LED goes out.
Two short beeps sound.
A short beep sounds and the yellow
LED goes out.
R
R
R
R
R
ELA
ELA
ELA
ELA
ELAY
Y
Y
Y
Y
MODE
MODE
MODE
MODE
MODE
Before programming a relay mode, you must have carried out the
procedure above, Assign Pulse, or latching function to relay 1 and/or
relay 2.
7.
7.
7.
7.
7.
Assign the relay action,
Pulse or latching.
Press ”1” for relay
output 1.
Press ”2” for relay
output 2.
Press ”00” for latching
(On/Off) function.
Press between 01 and
99 for a pulse function.
(e.g. 05 equals 5
seconds pulse).
8.
8.
8.
8.
8.
Press the “
K
” button.
9.
9.
9.
9.
9.
To leave the program, press
the ”#” button.
4
GB
GB
GB
GB
GB
A
A
A
A
A
SSIGNING
SSIGNING
SSIGNING
SSIGNING
SSIGNING
ONE
ONE
ONE
ONE
ONE
OR
OR
OR
OR
OR
TWO
TWO
TWO
TWO
TWO
RELA
RELA
RELA
RELA
RELAYS
YS
YS
YS
YS
/
/
/
/
/
USER
USER
USER
USER
USER
P
P
P
P
P
ROGRAM
ROGRAM
ROGRAM
ROGRAM
ROGRAM
MODE
MODE
MODE
MODE
MODE
1.
1.
1.
1.
1.
Enter the Engineering code.
Press the ”#” button.
2.
2.
2.
2.
2.
Type ”0”.
3.
3.
3.
3.
3.
Enter a user number, which
must be a two-digit number
between 01 and 99 (for
example, user code 2 is
“02”).
Then enter the PIN code,
which must be between 1
and 8 digits. For example,
PIN code 9874.
4.
4.
4.
4.
4.
Press the ”
K
” button.
5.
5.
5.
5.
5.
To program the next PIN
code, repeat steps 2 to 4.
6.
6.
6.
6.
6.
To leave the program, press
the ”#” button.
The yellow LED lights up and a long
beep sounds.
Example
Example
Example
Example
Example
of programming a card or a keyfob in memory
position 01:
Type: ”Engineering code” # 0 01 hold keyfob in front of
reader #
P
P
P
P
P
ROGRAMMING
ROGRAMMING
ROGRAMMING
ROGRAMMING
ROGRAMMING
A
A
A
A
A
CARD
CARD
CARD
CARD
CARD
OR
OR
OR
OR
OR
KEYFOB
KEYFOB
KEYFOB
KEYFOB
KEYFOB
Example :
Example :
Example :
Example :
Example :
Memory 01 position to be assigned to relay 2
Type: ”Engineering code” # 3 01 2
K
#
A short beep sounds after every
keystroke.
A short beep sounds after every
keystroke.
Example :
Example :
Example :
Example :
Example :
Relay 2 with pulse function of 5 seconds
Type: ”Engineering code” # 2 05