TECHNICAL DATA
Operating pressure and
temperature must be within
the limits depicted by the
hatched area
Operating temperatures above
100°C as depicted by the
shaded area must be avoided
for continuous operation
F
IG
. 3.1
A
T
EMPERATURE
P
RESSURE
D
IAGRAM
3.1 T
EMPERATURE
/ P
RESSURE
PUMP MODULE
Pipe connection
22mm
Reducers supplied
15mm
Pump type
15/40
Maximum operating pressure
0.6MPa
Electrical Cable
1.0mm² 3 core heat resistant flex 3093Y to 85°C
Cover
Moulded polystyrene
AIR SEPARATOR MODULE
Pipe connection
22mm
Reducers supplied
15mm
Maximum operating pressure
0.6MPa
Cover
Moulded polystyrene
EXPANSION VESSEL
2 & 3 collector systems
25l
Optional size (code 12002737)
35l
Maximum pressure
10 bar
Pre-charge pressure
2.5 bar
PRESSURE RELIEF VALVE
Setting
6 bar
Discharge
½” BSP - Ø15 pipe
HEAT TRANSFER FLUID
Type
Tyfocor LS
Use undiluted
100%
Weight
1.04kg/l
Frost protection
to -28°C