background image

GB

13

!

 Before operating your new appliance please read this

instruction booklet carefully. It contains important information

for safe use, installation and care of the appliance.

!

 Please keep these operating instructions for future

reference. Pass them on to possible new owners of the

appliance.

Positioning

!

 Keep packaging material out of the reach of children. It

can become a choking or suffocation hazard (

see

Precautions and tips

).

!

 The appliance must be installed by a qualified professional

according to the instructions provided. Incorrect installation

may cause harm to people and animals or may damage

property.

!

 This unit may be installed and used only in permanently

ventilated rooms in accordance with British Standard Codes

Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S. 6891

Current Editions. The following requirements must be

observed:
• The room must be equipped with an air extraction system

that expels any combustion fumes. This may consist of a

hood or an electric fan that automatically starts each time

the appliance is switched on.

• The room must also allow proper air circulation, as air is

needed for combustion to occur normally. The flow of air

must not be less than 2 m

3

/h per kW of installed power.

The air circulation system may

take air directly from the outside

by means of a pipe with an inner

cross section of  at least 100 cm

2

;

the opening must not be

vulnerable to any type of

blockages.

The system can also provide the

air needed for combustion

indirectly, i.e. from adjacent rooms

fitted with air circulation tubes as

described above. However, these

rooms must not be communal

rooms, bedrooms or rooms that

may present a fire hazard.

• Liquid petroleum gas sinks to the floor as it is heavier

than air. Therefore, rooms containing LPG cylinders must

also be equipped with vents to allow gas to escape in the

event of a leak. As a result LPG cylinders, whether

partially or completely full, must not be installed or stored

in rooms or storage areas that are below ground level

(cellars, etc.). It is advisable to keep only the cylinder

being used in the room, positioned so that it is not

subject to heat produced by external sources (ovens,

fireplaces, stoves, etc. ) which could raise the

temperature of the cylinder above 50°C.

Fitting the appliance

Gas and mixed hobs are manufactured with type X degree

protection against overheating. The following precautions

must be taken when installing the hob:
• Kitchen cabinets adjacent to the appliance and taller

than the top of the hob must be at least 600 mm from the

edge of the hob.

• Hoods must be installed according to their relative

installation instruction manuals and at a minimum

distance of 650 mm from the hob.

• Place the wall cabinets adjacent to the hood at a

minimum height of 420 mm from the hob (

see figure

).

If the hob is installed beneath a

wall cabinet, the latter must be

situated at a minimum of 700 mm

above the hob (

see figure

).

• The installation cavity should have the dimensions

indicated in the figure.

Fastening hooks are provided, allowing you to fasten the

hob to tops that are between 20 and 40 mm thick. To

ensure the hob is securely fastened to the top, we

recommend you use all the hooks provided.

555 mm

55 mm

475 mm

Hook fastening diagram

Hooking position

Hooking position

for top

 H=20 mm

for top 

H=30 mm

Installation

Enlarging the ventilation slot
between window and floor.

Adjacent
Room

Room to be
Vented

A

Examples of ventilation holes
for comburant air.

In a chimney stack or branched flue. 
(exclusively for cooking appliances)

Directly to 
the Outside

600mm min.

54

0mm min.

7

00mm min.

All manuals and user guides at all-guides.com

Summary of Contents for PZ 640

Page 1: ...ieme Avvio e utilizzo 7 Consigli pratici per l uso dei bruciatori Precauzioni e consigli 8 Sicurezza generale Smaltimento Manutenzione e cura 9 Escludere la corrente elettrica Pulire l apparecchio Man...

Page 2: ...idoni di GPL debbono prevedere delle aperture verso l esterno cos da permettere l evacuazione dal basso delle eventuali fughe di gas Pertanto i bidoni di GPL siano essi vuoti o parzialmente pieni non...

Page 3: ...bialamessaaterraesiaanormadilegge la presa sia in grado di sopportare il carico massimo di potenza della macchina indicato nella targhetta caratteristiche la tensione di alimentazione sia compresa nei...

Page 4: ...Regolazione minimi 1 Portare il rubinetto sulla posizione di minimo 2 Togliere la manopola ed agire sulla vite di regolazione posta all interno o di fianco all astina del rubinetto fino ad ottenere u...

Page 5: ...do Ridotto RR 100 0 70 2 60 41 80 189 186 2 60 110 Y 248 Semi Rapido S 75 0 40 1 65 30 64 120 118 1 65 96 157 Ausiliario A 55 0 40 1 00 30 50 73 71 1 00 79 95 Tripla Corona TC 130 1 30 3 30 57 87 240...

Page 6: ...sono di diverse dimensioni e potenze Scegliete quello pi adatto al diametro del recipiente da utilizzare Manopole di comando dei BRUCIATORI GAS per la regolazione della fiamma o della potenza Candela...

Page 7: ...ino all avvenuta accensione Nel caso di una estinzione accidentale delle fiamme del bruciatore chiudere la manopola di comando e ritentare l accensione dopo almeno 1 minuto Per spegnere il bruciatore...

Page 8: ...della corrente tirando il cavo bens afferrando la spina Non fare pulizia o manutenzione senza aver prima staccato la spina dalla rete elettrica In caso di guasto in nessun caso accedere ai meccanismi...

Page 9: ...eventuali incrostazioni Nei piani dotati di accensione automatica occorre procedere frequentemente ad una accurata pulizia della parte terminale dei dispositivi di accensione istantanea elettronica e...

Page 10: ...nze del piano Non avete premuto a fondo la manopola Non avete mantenuto premuta a fondo la manopola per un tempo sufficiente ad attivare il dispositivo di sicurezza Sono ostruiti i fori di fuoriuscita...

Page 11: ...one per fissare un appuntamento con il Centro Assistenza Tecnico Autorizzato pi vicino al luogo da cui si chiama attivo 7 giorni su 7 sabato e domenica compresi e non lascia mai inascoltata una richie...

Page 12: ...the appliance 17 Overall view Start up and use 18 Practical advice on using the burners Precautions and tips 19 General safety Disposal Maintenance and care 20 Switching the appliance off Cleaning the...

Page 13: ...eavier than air Therefore rooms containing LPG cylinders must also be equipped with vents to allow gas to escape in the event of a leak As a result LPG cylinders whether partially or completely full m...

Page 14: ...to the power supply make sure that The appliance is earthed and the plug is compliant with the law The socket can withstand the maximum power of the appliance which is indicated on the data plate The...

Page 15: ...to the low flame position 2 Remove the knob and adjust the adjustment screw which is positioned in or next to the tap pin until the flame is small but steady 3 Having adjusted the flame to the requir...

Page 16: ...0 41 80 189 186 2 60 110 Y 248 Semi Fast Medium S 75 0 40 1 65 30 64 120 118 1 65 96 157 Auxiliary Small A 55 0 40 1 00 30 50 73 71 1 00 79 95 Triple Crown TC 130 1 30 3 30 57 87 240 236 3 60 131 343...

Page 17: ...ware to choose the most appropriate burner to cook with Control Knobs for GAS BURNERS adjust the power or the size of the flame GAS BURNER ignition enables a specific burner to be lit automatically SA...

Page 18: ...keeping it pressed in until the burner lights If a flame is accidentally extinguished turn off the control knob and wait for at least 1 minute before trying to relight it To switch off the burner turn...

Page 19: ...ket do not pull on the cable Never carry out any cleaning or maintenance work without having detached the plug from the mains In case of malfunction under no circumstances should you attempt to repair...

Page 20: ...ed frequently with warm water and soap and any burnt on substances removed For hobs which ligth automatically the terminal part of the electronic instant lighting devices should be cleaned frequently...

Page 21: ...way in You keep the knob pressed in long enough to activate the safety device The gas holes are not blocked in the area corresponding to the safety device The gas holes are not blocked There are no d...

Page 22: ...n de l appareil 29 Vue d ensemble Mise en marche et utilisation 30 Conseils pratiques pour l utilisation des br leurs Pr cautions et conseils 31 S curit g n rale Mise au rebut Nettoyage et entretien 3...

Page 23: ...yst me d vacuation vers l ext rieur des fum es de combustion r alis au moyen d une hotte ou par ventilateur lectrique qui entre automatiquement en fonction d s que l on allume l appareil La pi ce doit...

Page 24: ...questions de s curit lectrique mais aussi pour simplifier au besoin l extraction du four Branchement du c ble d alimentation au r seau lectrique Montez sur le c ble une prise normalis e adapt e la cha...

Page 25: ...acier Le raccordement l installation de gaz doit tre effectu de mani re ce que l appareil ne subisse aucun type de contrainte La rampe d alimentation de l appareil est munie d un raccord en L orientab...

Page 26: ...ur les by pass en utilisant de la cire ou autre mat riau quivalent PLAQUETTE SIGNALETIQUE Raccordements lectriques 220 240V 50 60Hz Cet appareil est conforme aux Directives Communautaires suivantes 73...

Page 27: ...FR Nominale mbar Minimum mbar Maximum mbar 28 30 20 35 37 25 45 20 17 25 25 20 30 Pression de alimentation BE Nominale mbar Minimum mbar Maximum mbar 28 30 20 35 37 25 45 20 15 25 25 15 30 Tableau 1...

Page 28: ...llande Gaz naturels Br leur Diam tre mm Pouissance thermique kW p c s Injecteur 1 100 D bit l h Nominal R duit mm G25 Rapide Grand R 100 3 00 0 70 116 332 Rapide R duit RR 100 2 60 0 70 110 Y 288 Semi...

Page 29: ...x au diam tre de votre casserole Manettes de commande des BR LEURS GAZ pour le r glage de la flamme ou de la puissance La bougie d allumage des BR LEURS GAZ permet l allumage automatique du br leur s...

Page 30: ...il y ait allumage En cas d extinction accidentelle des flammes du br leur tournez la manette jusqu l arr t et attendez au moins 1 minute avant de tenter de rallumer Pour teindre le br leur tournez la...

Page 31: ...cher la fiche de la prise de courant N effectuez aucune op ration de nettoyage ou d entretien sans avoir auparavant d branch la fiche de la prise de courant En cas de panne n essayez en aucun cas d ac...

Page 32: ...soigneusement toute incrustation Dans le cas de tables quip es d allumage automatique nettoyez fr quemment et soigneusement l extr mit des dispositifs d allumage lectronique instantan et v rifiez que...

Page 33: ...s avez bien appuy fond sur la manette pendant un laps de temps suffisant pour permettre l activation du dispositif de s curit les orifices de sortie du gaz situ s en face du dispositif de s curit ne s...

Page 34: ...to Puesta en funcionamiento y uso 40 Consejos pr cticos para el uso de los quemadores Precauciones y consejos 41 Seguridad general Eliminaci n Mantenimiento y cuidados 42 Cortar la corriente el ctrica...

Page 35: ...contienen botellas de GPL deben tener aberturas hacia el exterior para permitir la evacuaci n desde abajo de eventuales escapes de gas Adem s las botellas de GPL vac as o parcialmente llenas no deben...

Page 36: ...da a las normas vigentes el conductor de tierra no debe ser interrumpido por el interruptor El cable de alimentaci n el ctrica se debe colocar de modo tal que no alcance en ning n punto una temperatur...

Page 37: ...ando las operaciones en sentido contrario 4 al finalizar la operaci n sustituya la anterior etiqueta de calibrado con la correspondiente al nuevo gas que se va a utilizar disponible en nuestros Centro...

Page 38: ...R pido Reducido RR 100 0 70 2 60 41 80 189 186 2 60 110 Y 248 Semi R pido Medio S 75 0 40 1 65 30 64 120 118 1 65 96 157 Auxiliar Peque o A 55 0 40 1 00 30 50 73 71 1 00 79 95 Triple Corona TC 130 1...

Page 39: ...el di metro del recipiente que va a utilizar Mandos de los QUEMADORES A GAS para la regulaci n de la llama o de la potencia Buj a de encendido de los QUEMADORES A GAS permite el encendido autom tico d...

Page 40: ...tencia manteni ndolo apretado hasta que se produzca el encendido Si se apagara accidentalmente la llama del quemador cierre el mando y vuelva a intentar encenderlo despu s de 1 minuto como m nimo Para...

Page 41: ...ufe No realice la limpieza o el mantenimiento sin haber desconectado primero el aparato de la red el ctrica En caso de aver a no acceda nunca a los mecanismos internos para intentar una reparaci n Lla...

Page 42: ...las incrustaciones En las encimeras que poseen encendido autom tico es necesario realizar frecuentemente una cuidadosa limpieza de la parte terminal de los dispositivos de encendido instant neo electr...

Page 43: ...o ha presionado a fondo el mando No ha mantenido presionado a fondo el mando por un tiempo suficiente como para activar el dispositivo de seguridad Est n obstruidos los orificios de salida del gas a l...

Page 44: ...ES 44 09 2005 195052706 01 XEROX BUSINESS SERVICES All manuals and user guides at all guides com...