Heat pump water heater – GENERAL INFORMATION
66
2.5 Technical data table
Description
Unit of
measurement
200
250
250 SYS
250 TWIN
SYS
Rated tank capacity
l
200
250
245
240
Insulation thickness
mm
≈ 50
Type of internal tank protection
Enamelling
Type of corrosion protection
Titanium impressed current anode + disposable
magnesium anode
Maximum operating pressure
MPa
0,6
Diameter of hydraulic connections
II
G 3/4 M
Diameter of condensate drainage connection
mm
14
Diameter of air exhaust/intake pipes
mm
150-160-200
Minimum water hardness
°F
12
Minimum conductivity of the water
µS/cm
150
Weight when empty
kg
90
95
115
130
Heating bottom circuit exchange surface
m
2
-
-
0,65
0,65
Heating top circuit exchange surface
m
2
-
-
-
0,65
Max water temperature with external integration
°C
-
-
75
75
Heat pump
Average electrical power consumption
W
700
Max. electrical power consumption
W
900
Quantity of R134a refrigerant fluid
kg
1,3
Max. pressure of refrigerating circuit (low-pressure
side)
MPa
1
Max. pressure of refrigerating circuit (high-pressure
side)
MPa
2,4
Max. water temperature with heat pump
ºC
62
EN 16147
COP (
A
)
3,05
3,35
3,14
3,21
Heating time (
A
)
h:min
04:30
05:23
05:29
05:43
Heating energy consumption (
A
)
kWh
2,934
3,552
3,718
3,795
Max. amount of hot water in a single intake V
max
(
A
),
delivered at 55°C
l
273
346
345
345
Pes (
A
)
W
23
22
24
26
Tapping (
A
)
L
XL
XL
XL
812/2013 – 814/2013
(
B
)
Q
elec
(
B
)
kWh
3,825
5,690
6,066
5,944
Ƞ
wh
(
B
)
%
126,1
137,0
128,5
131,5
Mixed water at 40°C V40 (
B
)
l
273
346
345
345
Temperature setting (
B
)
°C
55
55
55
55
Annual electricity consuption (average climatic
condition) (
B
)
kWh/year
812
1223
1303
1274
Load prifile (
B
)
L
XL
XL
XL
Indoor sound power level (
C
)
dB(A)
55
55
55
55