Positioning the unit

Installation modes

  Avoid installing the unit:

in positions subject to exposure to direct sunlight;

in proximity to sources of heat;

-  in damp areas or places with probable contact with 

water;

in places with oil fumes

in places subject to high frequency radio waves

  Make sure that:

-  the wall on which the unit is to be installed is strong 

enough to support the weight;

the part of the wall interested does not have pipes or 
electric wires passing through;

the interested wall is perfectly flat;

there is an area free of obstacles which could interfere 
with the inlet and outlet air flow;

the installation wall is preferably an outside perimeter 
wall to allow the discharge of the condensation outside.

The following descriptions of the various mounting phases 
and the relative designs refer to a version of the machine 
with fixtures on the left.
The operations for the mounting of machines with fixtures 
on the right are exactly the same.
Only the images are to be considered as a mirror image.
To ensure that the installation is performed correctly and 

that the appliance will perform perfectly carefully follow 
the instructions indicated in this manual. Failure to respect 
the rules indicated not only can cause malfunctions of the 
appliance but will also invalidate the warranty and hence 
Ariston shall not respond for any damage to persons, 
animals or property.

Minimum installation space

Figure indicates the minimum mounting distances between 
the wall-mounted cooler-convector and furniture present 

in the room.

Summary of Contents for NIMBUS AQUASLIM 10 FS

Page 1: ...ISTRUZIONI TECNICHE PER L INSTALLAZIONE E LA MANUTENZIONE TECHNICAL INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE NIMBUS AQUASLIM FS ...

Page 2: ...ettuata nel rispetto delle normative di sicurezza il rischio di subire danni fisici Tensione elettrica pericolosa Segnala al personale interessato che l operazione descritta presenta se non effettuata nel rispetto delle normative di sicurezza il rischio di subire uno shock elettrico Pericolo di forte calore Delle normative di sicurezza il rischio di subire bruciature per contatto con componenti co...

Page 3: ...to con cura e dovrà SEMPRE accompagnare l apparecchio anche in caso di sua cessione ad altro proprietario o utente oppure di un trasferimento su un altro impianto In caso di suo danneggiamento o smarrimento richiederne un altro esemplare al Servizio Tecnico di Assistenza Ariston di zona Gli interventi di riparazione o manutenzione devono essere eseguiti dal Servizio Tecnico di Assistenza o da pers...

Page 4: ...ione indica che il prodotto alla fine della propria vita utile deve essere raccolto separatamente dagli altri rifiuti L utente dovrà pertanto conferire l apparecchiatura giunta a fine vita agli idonei centri comunali di raccolta differenziata dei rifiuti elettrotecnici ed elettronici In alternativa alla gestione autonoma è possibile consegnare l apparecchiatura che si desidera smaltire al rivendit...

Page 5: ...ne sia possibilmente una parete di perimetro esterno per consentire lo scarico della condensa all esterno Le seguenti descrizioni sulle varie fasi di montaggio ed i relativi disegni fanno riferimento ad una versione di macchina con attacchi a sinistra Le descrizioni per le operazioni di montaggio delle macchine con attacchi a destra sono le medesime Solo le immagini sono da considerarsi rappresent...

Page 6: ...errando completamente le quattro viti Verificarne la stabilità spostando manualmente le staffe verso destra e sinistra alto e basso Montare l unità verificando il corretto aggancio sulle staffe e la sua stabilità N B al fine di agevolare il raccordo delle tubazioni agli attacchi del ventilconvettore raccomandiamo di installare una cassetta da incasso in corrispondenza dell uscita delle tubazioni s...

Page 7: ... Collegamenti idraulici N B il diametro nominale se non diversamente indicato fa sempre riferimento al diametro interno Per evitare formazione di condensa superficiale è sempre raccomandato installare kit valvole elettriche fatto salvo il caso in cui venga previsto un comando elettrico ad es testina elettrotermica a monte dell apparecchio La scelta ed il dimensionamento delle linee idrauliche è de...

Page 8: ...rale per l installazione orizzontale la posizione della pompa deve essere decisa in funzione delle specifiche esigenze Tali pompe si trovano comunemente in commercio E comunque opportuno al termine dell installazione verificare il corretto deflusso del liquido di condensa versando molto lentamente circa 1 2 l di acqua in circa 5 10 minuti nella vaschetta di raccolta Collegare al raccordo di scaric...

Page 9: ...li o automatici Iniziare il riempimento aprendo lentamente il rubinetto di carico acqua impianto Per i modelli installati in posizione verticale agire utilizzando un cacciavite sulla sfiato della batteria posto più in alto Per gli apparecchi installati in posizione orizzontale agire sullo sfiato posizionato più in alto Quando comincia ad uscire acqua dalle valvole di sfiato dell apparecchio chiude...

Page 10: ...itare che la valvola rimanga sempre aperta Collegamenti elettrici Effettuare i collegamenti elettrici attenendosi alle prescrizioni riportate nei capitoli Avvertenze generali e Regole fondamentali di sicurezza facendo riferimento agli schemi presenti nei manuali d installazione degli accessori Prima di effettuare qualsiasi intervento assicurarsi che l alimentazione elettrica sia disinserita L appa...

Page 11: ...terruttore generale di alimentazione Attendere il raffreddamento dei componenti per evitare il pericolo di scottature Non usare spugne abrasive o detergenti abrasivi o corrosivi per non danneggiare le superfici verniciate Quando necessario pulire le superfici esterne del ventilconvettore NIMBUS AQUASLIM FS con un panno morbido e inumidito con acqua Pulizia filtro aspirazione aria Dopo un periodo d...

Page 12: ...n interruttore di sicurezza che impedisce il funzionamento del ventilatore in assenza o con pannello mobile mal posizionato Dopo le operazioni di pulizia del filtro verificare il corretto montaggio del pannello Pulizia setti filtranti Filtro Lembo inferiore Sede del filtro Consigli per il risparmio energetico Mantenere costantemente puliti i filtri mantenere per quanto possibile chiuse porte e fin...

Page 13: ...one della ventola Il microinterruttore che ferma la ventilazione all apertura della griglia filtro non si chiude correttamente Controllare che la chiusura della griglia determini l attivazione del contatto del microinterruttore I collegamenti elettrici non sono corretti Verificare i collegamenti elettrici L apparecchio perde acqua in funzione riscaldamento Perdite nell allacciamento idraulico dell...

Page 14: ...ry if not performed according to the safety rules Danger of high voltage Signals that the operation described could cause electrocution if not performed according to the safety rules Danger due to heat Signals that the operation described could cause burns if not performed according to the safety rules Do Not Refers to actions that absolutely must not be performed Conformity 14 Symbols 14 Safety p...

Page 15: ...ect air flow Do not leave the room closed for long periods Periodically open the windows to ensure a correct change of air This instruction leaflet is an integral part of the appliance and consequently must be kept carefully and must ALWAYS accompany the appliance even when it is passed to a new owner or user or transferred onto another system If it is lost or damaged please contact the local Aris...

Page 16: ...red to a waste disposal site for electric and electronic equipment or returned to the dealer when purchasing a new device of the same kind Theuserisresponsiblefordeliveringthedecommissioned device to a suitable waste disposal site Proper separated collection of the decommissioned device and its subsequent eco compatible recycling treatment and disposal helps to prevent negative effects on the envi...

Page 17: ...eter wall to allow the discharge of the condensation outside The following descriptions of the various mounting phases and the relative designs refer to a version of the machine with fixtures on the left The operations for the mounting of machines with fixtures on the right are exactly the same Only the images are to be considered as a mirror image To ensure that the installation is performed corr...

Page 18: ...s can be adjusted with a spirit level Fully tighten the four screws to block the two brackets Check the stability by manually moving the brackets to the right and to the left up and down Mount the unit checking that it fits correctly onto the brackets and checking that it is stable N B to facilitate the connection of the pipes to the fan coil connections we recommend installing a built in box at t...

Page 19: ...vailable as accessories 3301561 3301562 3301563 3301564 Carefully check the inclination of the exhaust pipe Any counterslope of the discharge line can cause water leakage Wall plugs Brackets Screws Drainage pipe Hydraulic connections The choice and sizing of the hydraulic lines must be made by an expert who must operate according to the rules of good technique and the laws in force taking into acc...

Page 20: ...ount the pump under the lateral drainage tray with the horizontal installation the pump s position must be decided on the basis of the specific necessities Such pumps are commonly found in commerce However on completion of the installation it is advisable to check the correct outflow of the condensation liquid by slowly pouring about l of water into the collection tray in about 5 10 minutes Connec...

Page 21: ...by slowly opening the system water filling tap For the unit installed in a vertical position take a screwdriver and open the highest breather of the heat exchanger For appliances installed horizontally open the breather positioned higher up When water starts coming out of the breather valves of the appliance close them and continue filling until reaching the nominal value for the system Check the ...

Page 22: ...e thermostatic head before starting the system Electrical connections Make electrical connections according to the requirements set out in sections General Warnings and Foundamental Safety Rules by reference to the patterns present in the installation and accessories manuals Before doing any work make sure the power is switched off The unit must be connected to the mains through a multipolar switc...

Page 23: ...the mains by switching off the master switch Wait until the parts have cooled down to avoid the risk of burns Do not use abrasive sponges or abrasive or corrosive detergents to avoid damaging the painted surfaces When necessary clean the outer surfaces of the NIMBUS AQUASLIM FS cooler convector with a soft cloth damp cloth Cleaning air suction filter After a period of continuous operation and in c...

Page 24: ...he appliance is fitted with a safety switch that prevents the operation of the fan with the mobile panel missing or out of position After finishing the cleaning of the filter check that the panel is mounted correctly Cleaning filtering seats Filter Lower edge Filter housing Energy saving tips Always keep the filters clean when far possible keep the doors and windows closed in the room being condit...

Page 25: ... the motor and thefree rotation of the fan The micro switch that stops the ventilation when the filter grill is opened does not close correctly Check that by closing the grill the micro switch contact is activated The electrical connections are not correct Check the electrical connections The appliance leaks water during the heating function Leaks in the hydraulic connections of the system Check t...

Page 26: ......

Page 27: ......

Page 28: ...420011081800 01 2020 Ariston SpA Viale Aristide Merloni 45 60044 Fabriano AN Italy Telefono 0732 6011 Fax 0732 602331 info it aristonthermo com Servizio Clienti Ariston Telefono 0732 633528 ...

Reviews: