the correct level the boiler will ignite
automatically. If there are frequent drops in
pressure within the system, have a plumber
check the heating system for possible water
leaks.

Temporary shutdown due to

defective discharge of exhaust

fumes

The boiler is fitted with safety devices,
which in the event of a defective discharge
of exhaust fumes, automatically interrupts
the gas supply, thereby shutting off the
boiler.
The shut-off of the boiler is temporary for a
period of about 15 minutes.
Once this time period has passed and the

discharge state of exhaust fumes has
returned to normal, the boiler automatically
turns back on.
Important!
If this situation occurs frequently, contact an
Authorised Service Centre. so that they
may check that the exhaust fumes are
being expelled correctly and that the area
is ventilated properly.

Frost protection

The boiler is fitted with a thermostat which,
in the event that the water temperature
goes below 6°C, the burner turns on at
minimum power until the water in the boiler
has reached a temperature of about 20°C.
This device is only activated when the
boiler is operating perfectly and:

Summary of Contents for micro SYSTEM 10 RFFI

Page 1: ...d I n d E s t a t e O f f H o c k n e y R o a d B r a d f o r d B D 8 9 H Q 0 1 2 7 4 4 8 8 3 8 8 w w w h e a t i n g s p a r e s 2 4 7 c o m Unit 3A Thornton Road Ind Estate Off Hockney Road Bradfor...

Page 2: ...lid for 12 months from the first day of installation Repairs to the electric hydraulic or gas circuits may be carried out only by your local authorised MTS Servicing Centre Every attempt has been made...

Page 3: ...dditional information please consult the Installation and Servicing Instructions Make sure to keep the manuals provided with the appliance so that they can be used by the end user installer or our aut...

Page 4: ...ent use Do not allow children or inexperienced persons to use the appliance without supervision If you smell gas in the room do not turn on light switches use the telephone or any other object which m...

Page 5: ...ominal Pressure Liquid Gas G30 G31 kW kW C bar litres V Hz W IP mbar mbar 15 4 14 1 82 4 82 42 3 0 7 6 230 50 115 X4D 20 30 37 11 6 10 5 81 3 82 42 3 0 7 6 230 50 105 X4D 20 30 37 15 kW 10 kW 22 7 10...

Page 6: ...T h o r n t o n R o a d I n d E s t a t e O f f H o c k n e y R o a d B r a d f o r d B D 8 9 H Q 0 1 2 7 4 4 8 8 3 8 8 w w w h e a t i n g s p a r e s 2 4 7 c o m Unit 3A Thornton Road Ind Estate Off...

Page 7: ...n the appliance it must not be used until the fault has been corrected by a competent person 7 LEGEND A On Off button B On Off L E D green frost protection active C Central Heating button D Cental Hea...

Page 8: ...e wiped with either a damp or dry cloth Spray polishes must not be used on the control panel surface or knobs Care must be taken in preventing any liquid entering the appliance PRACTICAL TIPS If the w...

Page 9: ...expected the boiler and system pipe work should be drained in order to prevent frost damage To improve comfort and take full advantage of the heat produced by the boiler it is recommended that an exte...

Page 10: ...he heating It is possible to set the temperature of the heating system by adjusting the knob G between 1 and 5 until the stop on the ECO position This will vary temperature from approximately 40 C to...

Page 11: ...erature of the heating system be set by means of the knob G at the ECO position This will allow the regulation of the external temperature to operate effectively and obtain energy efficiency and good...

Page 12: ...st of these situations are communicated by means of the red L E D F and at times the user may be able to remedy them Shutdown due to ignition failure In the event that the automatic ignition of the bu...

Page 13: ...13 Should the boiler fail to ignite a second time check that the external gas cock is open If the problem persists contact an Authorised Service Centre Shutdown due to overheating In the event that t...

Page 14: ...tomatically turns back on Important If this situation occurs frequently contact an Authorised Service Centre so that they may check that the exhaust fumes are being expelled correctly and that the are...

Page 15: ...ed 4 MAINTENANCE Schedule an annual maintenance check up for the boiler with a competent person Correct maintenance always results in savings in the cost of running the system 5 CHANGE OF GAS TYPE Our...

Page 16: ...01494 459775 Internet http www mtsgb ltd uk E mail info mtsgb ltd uk Technical Service Hot Line 01494 539579 U n i t 3 A T h o r n t o n R o a d I n d E s t a t e O f f H o c k n e y R o a d B r a d f...

Reviews: