17
Ⅸ.
Specification list
E5
E6
E7
E8
45min timing action
False flame
Fan failure or abnormal rotation
Communication failure
Stop the water supply and restart.
Stop the water and restart. If there is still
problem, please contact our serviceman.
Please contact our serviceman.
Stop the water supply and restart. If there is
still problem, please contact our serviceman.
●If the display does not turn bright even if power supply button is pressed down, please disconnect the
plug and try once more. If the display still keeps off, please contact our serviceman.
Model
Gas category
Rated gas pressure
Heat input
Production capacity
Exhaust type
Heat efficiency
Ignition
Min. startup water pressure
Operating water pressure
Gi7S 16L FFI Gi7S 11L FFI
Liquefied petroleum gas
2.8KPa
Natural gas
2.0KPa
2.8KPa
Natural gas
2.0KPa
32KW
16L/ min (temperature rise: 25
℃
)
22KW
11L/ min (temperature rise: 25
℃
)
FFI Model
>88%
Water-flow electrical pulse ignition
0.02MPa
0.04MPa~0.4MPa
Electronic proportional valve+ electronic fire-intensity shift valve
Software startup
R1/2”
R3/4”
Φ60mm/Φ100mm
AC220V/50HZ
48W
42W
DC motor
1.5m
156W
563x350x130mm
Control
Pipe
connection
Electric
characteristic
Hot-water
temperature
control
Delay ignition
Water-in/out
pipe
Gas-in pipe
Gas-out pipe
Voltage/Frequency
Rated power
Blower
Wire
Electrical heating power (for
anti-freezing model)
Dimension
18
Ⅹ
. Wiring diagram
Liquefied petroleum gas
Summary of Contents for Marco Polo Gi7S 11L FFI
Page 11: ...19 20 20 21 23 24 27 28 29 33 34 35 ...
Page 12: ...a Gi7S 11L FFI b Gi7S 16L FFI 21 22 ...
Page 13: ...23 24 ...
Page 14: ...25 26 ...
Page 15: ...27 28 ...
Page 16: ...29 30 ...
Page 17: ...31 32 ...
Page 18: ...33 34 ...