technical area
37
8. 2
BOILER
8. 2. 1
Fan Status
0 = OFF
1 = ON
8. 2. 2
Fan Speed - x100 RPM
8. 2. 3
Aperto
8. 2. 4
Diverter valve position
0 = D.H.W.
1 = Central Heating
8. 2. 5
D.H.W. Flow Rate (l/min)
8. 2. 7
Pump Modulation (%)
8. 2. 8
Gas Power (kW)
8. 3
BOILER TEMPERTURE
8. 3. 0
Set temperature Central Heating(°C)
8. 3. 1
Flow Heating temperature (°C)
8. 3. 2
Return Heating temperature (°C)
8. 3. 3
Domestic Hot Water Temperature (°)
8. 3. 5
Outdoor temperature (%)
Only with external sensor connected
8. 4
SOLAR & STORAGE
8. 4. 0
Storage Measured Temperature (°C)
8. 4. 2
D.H.W. Inlet Temperature (°C)
Display only with Solar Kit or external storage Kit
8. 5
SERVICE
8. 5. 0
Months to next
maintenance
from 0 to 60
(month)
24
If setted the boiler will display that is time to call the
installer for maintenance
Warning 3P9
Sched.Maintanace-Call Service
ALERT
8. 5. 1
Enable Maintenance
advice
0 = OFF
1 =ON
0
8. 5. 2
Maintenance Warning
Reset
Reset? OK= Yes Esc
= No
to erase the advice for maintenance
8. 5. 4
P.C.B Hardware version
8. 5. 5
P.C.B Software version
8. 6
ERROR HISTORY
8. 6. 0
Last 10 errors
from Error 0 to Error 9
This parameter makes it possible to see the last 10 errors
shown by the boiler as well as the relevant day, month
and year.
Turning the encoder allows for viewing the sequence of
errors that occurred, from 0 to 9.
Fault 3
No flame detected
501
12:18 24/01/2012
8.6.0 Last 10 errors
8. 6. 1
Reset Error List
Reset?
Ok=Yes
Esc=No
menu
sub
-menu
par
ameter description
value
default
setings