COMMISSIONING
Gas setting table
Gas Changeover
The appliance may be adjusted so that it may be used
with Liquid Gas (G30/G31) instead of methane gas (G20)
or vice-versa. The adjustment must be performed by a
Qualified Technician using the special Kit.
FAST R X ONM 11 EU
FAST R X ONM
14 EU
G20
G30
G31
G20
G30
G31
lower Wobbe index
(15°C, 1013 mbar)
MJ/m
3
45,67 80,58
70,69
45,67
80,58
70,69
Gas inlet pressure
mbar
20
29
37
20
29
37
Gas Burner Pressure max
mbar
11,4
24,8
31,8
13,4
27,2
34,8
Gas Burner Pressure min
mbar
2
5,3
6,7
2,2
4,6
5,65
Main Burner jets
nr.
12 x 2
14 x 2
Ø burner jets
mm
0.85*24
0.5*22/0.47*2
0.85*24
0.5*24/0.48*4
Max/min consumption
(15°C, 1013 mbar) (G.N.= m
3
/h) (LPG kg/h))
max
2,26
0,648
0,827
2,83
0,804
1,035
min
0,88
0,284
0,368
1,084
0,313
0,398