B029
10. Remove the pipe from the pressure gauge and connect screw “C” to the
pressure outlet in order to seal off the gas.
11. Carefully check the pressure outlets for gas leaks (valve inlet
and outlet).
IMPORTANT!
Whenever you disassemble and reassemble the gas connections, always
check for leaks using a soap and water solution.
Setting the anti-cycling device
This appliance is equipped with a potentiometer which delays the ignition of
the heating control and is situated on the P.C.B. (see the electrical diagrams).
By adjusting the potentiometer, it is possible to change the time interval
between the burner shutting down and its next ignition.
It is preset at 1 minute and can be adjusted from 0 to 2 minutes.
Use this control in particular situations where continuous shutting down and
ignition of the main burner occurs.
Anti-cycling
Device
Soft-light
Adjustment
Max. Heating
Adjustment
Removing the spark generator (SIT Sigma gas valve)
1.
Disconnect ignition leads “U” by pulling upwards
(see fig. 1.30);
2.
Remove the screws “V” (see fig. 1.31) with a Pozidrive
No. 2 star tip screwdriver;
3.
Remove the spark generator.
Fig. 1.30
Fig. 1.31
Fig. 1.32
U
V
Summary of Contents for EuroCombi Type C 23 MFFI
Page 21: ...Supplied By www heating spares co Tel 0161 620 6677 21 B029...
Page 22: ...Supplied By www heating spares co Tel 0161 620 6677 22 B029...
Page 23: ...Supplied By www heating spares co Tel 0161 620 6677 23 B029...
Page 24: ...Supplied By www heating spares co Tel 0161 620 6677 24 B029...
Page 26: ...Supplied By www heating spares co Tel 0161 620 6677 26 B029 A 23 MFFI A 27 MFFI...
Page 27: ...Supplied By www heating spares co Tel 0161 620 6677 27 B029 4 SHORT SPARE PARTS LIST A 23 MFFI...
Page 28: ...Supplied By www heating spares co Tel 0161 620 6677 28 B029 A 23 MFFI...
Page 30: ...Supplied By www heating spares co Tel 0161 620 6677 30 B029 A 27 MFFI...
Page 31: ...Supplied By www heating spares co Tel 0161 620 6677 31 B029...