16
B029
Removing the pump
1. Unscrew “Z” and remove the electrical connection
(see fig. 1.41);
2. Release the nuts “A1” and remove the pump
(see fig. 1.42).
Removing the pressure gauge
1. Remove the inspection panel
(see fig. 1.6 - 1.7);
2. Release coupling “A2” using a 14 mm open ended
spanner
(see fig. 1.43);
3. Push the pressure gauge through the control panel
from the rear
(see fig. 1.44).
A1
A1
Z
A2
Fig. 1.41
Fig. 1.42
Fig. 1.43
Fig. 1.44