Ariston EHP750T/HA Operating Instructions Manual Download Page 13

GB

13

Hook fastening diagram

 

Hooking position 

Hooking position

for top 

H=20mm

 

for top 

H=30mm

 

Front

 

Hooking position 

Back

for top 

H=40mm

!

 Use the hooks contained in the “accessory pack”.

•  Where  the  hob  is  not  installed  over  a  built-in  oven,  a 

wooden panel must be installed as insulation. This must 

be placed at a minimum distance of 20 mm from the lower 

part of the hob.

Ventilation

To ensure adequate ventilation, the back panel of the cabinet 

must be removed. It is advisable to install the oven so that it 

rests on two strips of wood, or on a completely flat surface 

with an opening of at least 45 x 560 mm (see diagrams).

 

560 mm

.

45 mm.

!

 he hob can only be installed above built-in ovens with a 

cooling ventilation system.

 

Electrical connection

Hobs equipped with a three-pole power supply cable are 

designed to operate with alternating current at the voltage 

and frequency indicated on the data plate (this is located 

on the lower part of the appliance). The earth wire in the 

cable has a green and yellow cover. If the appliance is to 

be installed above a built-in electric oven, the electrical 

connection of the hob and the oven must be carried out 

separately, both for electrical safety purposes and to make 

extracting the oven easier. 

Connecting the supply cable to the mains

Install a standardised plug corresponding to the load 

indicated on the data plate. 

The appliance must be directly connected to the mains 

using an omnipolar circuit-breaker with a minimum contact 

opening of 3 mm installed between the appliance and the 

mains.  The circuit-breaker must be suitable for the charge 

indicated and must comply with current electrical regulations 

(the earthing wire must not be interrupted by the circuit-

breaker). The supply cable must not come into contact with 

surfaces with temperatures higher than 50°C.

!

 The installer must ensure that the correct electrical 

connection has been made and that it is compliant with 

safety regulations.

Before connecting to the power supply, make sure that:

•  The appliance is earthed and the plug is compliant with 

the law.

•  The socket can withstand the maximum power of the 

appliance, which is indicated on the data plate.

•  The voltage is in the range between the values indicated 

on the data plate.

•  The socket is compatible with the plug of the appliance. 

If the socket is incompatible with the plug, ask an 

authorised technician to replace it. Do not use extension 

cords or multiple sockets.

!

 Once the appliance has been installed, the power supply 

cable and the electrical socket must be easily accessible.

!

 The cable must not be bent or compressed.

!

 The cable must be checked regularly and replaced by 

authorised technicians only (see Assistance).

!

 The manufacturer declines any liability should these safety 

measures not be observed.

Gas connection

The appliance should be connected to the main gas supply 

or to a gas cylinder in compliance with current national 

regulations. Before carrying out the connection, make sure 

the cooker is compatible with the gas supply you wish to 

use. If this is not the case, follow the instructions indicated 

in the paragraph “Adapting to different types of gas.”

When using liquid gas from a cylinder, install a pressure 

regulator which complies with current national regulations.

!

 Check that the pressure of the gas supply is consistent with the 

values indicated in Table 1 (“Burner and nozzle specifications”). 

This will ensure the safe operation and longevity of your 

appliance while maintaining efficient energy consumption.

Connection with a rigid pipe (copper or steel)

!

 Connection to the gas system must be carried out in such a 

way as not to place any strain of any kind on the appliance.

There is an adjustable L-shaped pipe fitting on the appliance 

supply ramp and this is fitted with a seal in order to prevent 

leaks. The seal must always be replaced after rotating the 

pipe fitting (seal provided with appliance). The gas supply 

pipe fitting is a threaded 1/2 gas cylindrical male attachment.

Summary of Contents for EHP750T/HA

Page 1: ...ance 5 Installation 12 Start up and use 16 Precautions and tips 16 Maintenance and care 17 Troubleshooting 17 Italiano Istruzioni per l uso PIANO Sommario Istruzioni per l uso 1 Avvertenze 2 Assistenz...

Page 2: ...ulizia dell apparecchio Eliminare eventuali liquidi presenti sul coperchio prima di aprirlo Non chiudere il coperchio in vetro se presente con i bruciatori gas o la piastra elettrica ancora caldi L ap...

Page 3: ...before opening it Do not close the glass cover if present when the gas burners or electric hotplates are still hot The appliance is not intended to be operated by means of an external timer or separat...

Page 4: ...il cliente che aderisce al programma Airbag avr diritto gratuitamente a l intervento entro 48 ore dalla chiamata il contributo per spese di trasferta del Tecnico diritto di chiamata la manodopera le p...

Page 5: ...ca del bruciatore prescelto DISPOSITIVO DI SICUREZZA in caso di spegnimento accidentale della fiamma interrompe l uscita del gas Presente solo in alcuni modelli Description of the appliance Overall vi...

Page 6: ...on siano parti comuni dell immobile o ambienti con pericolo di incendio o camere da letto A Esempi di aperture di ventilazione per l aria comburente Maggiorazione della fessura fra porta e pavimento L...

Page 7: ...del corretto collegamento elettrico e dell osservanza delle norme di sicurezza Prima di effettuare l allacciamento accertarsi che la presa abbia la messa a terra e sia a norma di legge la presa sia in...

Page 8: ...Tecnica Regolazione aria primaria dei bruciatori I bruciatori non necessitano di nessuna regolazione dell aria primaria Regolazione minimi 1 Portare il rubinetto sulla posizione di minimo 2 Togliere l...

Page 9: ...186 2 60 110 Y 248 Semi Rapido S 75 0 40 1 90 28 70 138 136 1 90 106 181 Ausiliario A 55 0 40 1 00 28 50 73 71 1 00 79 95 Tripla Corona TC 130 1 50 3 30 61 91 240 236 3 60 145 H1 343 Pressioni di alim...

Page 10: ...stato progettato e costruito in conformit alle norme internazionali di sicurezza Queste avvertenze sono fornite per ragioni di sicurezza e devono essere lette attentamente Sicurezza generale Questo ap...

Page 11: ...frequentemente con acqua calda e detersivo avendo cura di eliminare le eventuali incrostazioni Nei piani dotati di accensione automatica occorre procedere frequentemente ad una accurata pulizia della...

Page 12: ...ion tubes as described above However these rooms must not be communal rooms bedrooms or rooms that may present a fire hazard A Examples of ventilation holes for comburant air Enlarging the ventilation...

Page 13: ...ection has been made and that it is compliant with safety regulations Before connecting to the power supply make sure that The appliance is earthed and the plug is compliant with the law The socket ca...

Page 14: ...the tap to the low flame position 2 Remove the knob and adjust the adjustment screw which is positioned in or next to the tap pin until the flame is small but steady 3 Having adjusted the flame to th...

Page 15: ...6 2 60 110 Y 248 Semi Fast S 75 0 40 1 90 28 70 138 136 1 90 106 181 Auxiliary A 55 0 40 1 00 28 50 73 71 1 00 79 95 Triple Crown TC 130 1 50 3 30 61 91 240 236 3 60 145 H1 343 Supply Pressures Nomina...

Page 16: ...s provided in the paragraph on Positioning the appliance These instructions are only valid for the countries whose symbols appear in the manual and on the serial number plate The appliance was designe...

Page 17: ...tomatically the terminal part of the electronic instant lighting devices should be cleaned frequently and the gas outlet holes should be checked for blockages Stainless steel can be marked by hard wat...

Page 18: ...18 GB...

Page 19: ...GB 19...

Page 20: ...20 RS 195089032 01 09 2012 XEROX FABRIANO...

Reviews: