 Before operating your new appliance please read this 

instruction booklet carefully. It contains important information 

for safe use, installation and care of the appliance.

!

 Please keep these operating instructions for future reference. 

Pass them on to possible new owners of the appliance.

Positioning

!

 Keep packaging material out of the reach of children. It can 

become a choking or suffocation hazard (see Precautions 

and tips).

!

 The appliance must be installed by a qualified professional 

according to the instructions provided. Incorrect installation 

may cause harm to people and animals or may damage 

property.

!

 This unit may be installed and used only in permanently 

ventilated rooms in accordance with British Standard 

Codes Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S. 

6891  Current  Editions. The  following  requirements  must 

be observed:

•  The room must be equipped with an air extraction system 

that expels any combustion fumes. This may consist of 

a hood or an electric fan that automatically starts each 

time the appliance is switched on.

In a chimney stack or branched flue. 

(exclusively for cooking appliances)

Directly to 

the Outside

•  The room must also allow proper air circulation, as air is 

needed for combustion to occur normally. The flow of air 

must not be less than 2 m

3

/h per kW of installed power.

The air circulation system may 

take air directly from the outside 

by means of a pipe with an inner 

cross section of  at least 100 cm

2

the opening must not be vulnerable 

to any type of blockages.

The system can also provide the air 

needed for combustion indirectly, 

i.e. from adjacent rooms fitted with 

air circulation tubes as described 

above. However, these rooms must 

not be communal rooms, bedrooms 

or  rooms  that  may  present  a  fire 

hazard.

A

Examples of 
ventilation holes 
for comburant air.

Enlarging the ventilation slot

between window and floor.

Adjacent

Room

Room to be

Vented

•  Liquid petroleum gas sinks to the floor as it is heavier 

than air. Therefore, rooms containing LPG cylinders must 

also be equipped with vents to allow gas to escape in 

the event of a leak. As a result LPG cylinders, whether 

partially or completely full, must not be installed or stored 

in rooms or storage areas that are below ground level 

(cellars, etc.). It is advisable to keep only the cylinder 

being used in the room, positioned so that it is not subject 

to heat produced by external sources (ovens, fireplaces, 

stoves, etc. ) which could raise the temperature of the 

cylinder above 50°C.

Fitting the appliance

Gas and mixed hobs are manufactured with type X degree 

protection against overheating. The following precautions 

must be taken when installing the hob:

•  Kitchen cabinets adjacent to the appliance and taller than 

the top of the hob must be at least 600 mm from the edge 

of the hob.

•  Hoods  must  be  installed  according  to  their  relative 

installation instruction manuals and at a minimum 

distance of 650 mm from the hob.

•  Place the wall cabinets adjacent to the hood at a minimum 

height of 420 mm from the hob (see figure).

If the hob is installed beneath a wall 

cabinet, the latter must be situated 

at a minimum of 700 mm above the 

hob (see figure).

•  The  installation  cavity  should  have  the  dimensions 

indicated in the figure.

  Fastening hooks are provided, allowing you to fasten 

the hob to tops that are between 20 and 40 mm thick. 

To ensure the hob is securely fastened to the top, we 

recommend you use all the hooks provided.

555 mm

55 mm

475 mm

600mm min.

420mm min.

700mm min.

Summary of Contents for EHP750T/HA

Page 1: ...ance 5 Installation 12 Start up and use 16 Precautions and tips 16 Maintenance and care 17 Troubleshooting 17 Italiano Istruzioni per l uso PIANO Sommario Istruzioni per l uso 1 Avvertenze 2 Assistenz...

Page 2: ...ulizia dell apparecchio Eliminare eventuali liquidi presenti sul coperchio prima di aprirlo Non chiudere il coperchio in vetro se presente con i bruciatori gas o la piastra elettrica ancora caldi L ap...

Page 3: ...before opening it Do not close the glass cover if present when the gas burners or electric hotplates are still hot The appliance is not intended to be operated by means of an external timer or separat...

Page 4: ...il cliente che aderisce al programma Airbag avr diritto gratuitamente a l intervento entro 48 ore dalla chiamata il contributo per spese di trasferta del Tecnico diritto di chiamata la manodopera le p...

Page 5: ...ca del bruciatore prescelto DISPOSITIVO DI SICUREZZA in caso di spegnimento accidentale della fiamma interrompe l uscita del gas Presente solo in alcuni modelli Description of the appliance Overall vi...

Page 6: ...on siano parti comuni dell immobile o ambienti con pericolo di incendio o camere da letto A Esempi di aperture di ventilazione per l aria comburente Maggiorazione della fessura fra porta e pavimento L...

Page 7: ...del corretto collegamento elettrico e dell osservanza delle norme di sicurezza Prima di effettuare l allacciamento accertarsi che la presa abbia la messa a terra e sia a norma di legge la presa sia in...

Page 8: ...Tecnica Regolazione aria primaria dei bruciatori I bruciatori non necessitano di nessuna regolazione dell aria primaria Regolazione minimi 1 Portare il rubinetto sulla posizione di minimo 2 Togliere l...

Page 9: ...186 2 60 110 Y 248 Semi Rapido S 75 0 40 1 90 28 70 138 136 1 90 106 181 Ausiliario A 55 0 40 1 00 28 50 73 71 1 00 79 95 Tripla Corona TC 130 1 50 3 30 61 91 240 236 3 60 145 H1 343 Pressioni di alim...

Page 10: ...stato progettato e costruito in conformit alle norme internazionali di sicurezza Queste avvertenze sono fornite per ragioni di sicurezza e devono essere lette attentamente Sicurezza generale Questo ap...

Page 11: ...frequentemente con acqua calda e detersivo avendo cura di eliminare le eventuali incrostazioni Nei piani dotati di accensione automatica occorre procedere frequentemente ad una accurata pulizia della...

Page 12: ...ion tubes as described above However these rooms must not be communal rooms bedrooms or rooms that may present a fire hazard A Examples of ventilation holes for comburant air Enlarging the ventilation...

Page 13: ...ection has been made and that it is compliant with safety regulations Before connecting to the power supply make sure that The appliance is earthed and the plug is compliant with the law The socket ca...

Page 14: ...the tap to the low flame position 2 Remove the knob and adjust the adjustment screw which is positioned in or next to the tap pin until the flame is small but steady 3 Having adjusted the flame to th...

Page 15: ...6 2 60 110 Y 248 Semi Fast S 75 0 40 1 90 28 70 138 136 1 90 106 181 Auxiliary A 55 0 40 1 00 28 50 73 71 1 00 79 95 Triple Crown TC 130 1 50 3 30 61 91 240 236 3 60 145 H1 343 Supply Pressures Nomina...

Page 16: ...s provided in the paragraph on Positioning the appliance These instructions are only valid for the countries whose symbols appear in the manual and on the serial number plate The appliance was designe...

Page 17: ...tomatically the terminal part of the electronic instant lighting devices should be cleaned frequently and the gas outlet holes should be checked for blockages Stainless steel can be marked by hard wat...

Page 18: ...18 GB...

Page 19: ...GB 19...

Page 20: ...20 RS 195089032 01 09 2012 XEROX FABRIANO...

Reviews: