39
SETTINGS - ADJUSTMENT - PROBLEM IDENTIFICATION MENUS
4
4 ZONE DEVICE MANAGEMENT
4
4
0
NOT PRESENT
5 ZONE 2 PARAMETER
5
0 ZONE 2 TEMPERATURE SETTING
5
0
0 NOT PRESENT
5
0
1 NOT PRESENT
5
0
2 NOT PRESENT
5
1 Entering access code
222 press the programming "+" button to
select 234 and press the m
eNu
button
5
2 CYLINDER SETTING
5
2
0 Heating appliance temperature value setting
0 = from 20 to 45°C (low temperature)
1 = from 35 to 85°C (high
temperature)
1
select in the appliance type base
5
2
1 Basic heating control type selection type depending
on the peripheral devices connected
0 = fixed flow temperature
1 = device On/Off
2 = ambient sensor only
3 = external sensor only
4 = ambient external sensor
0
To activate heating control, press
the AUTO button. The Auto light is
illuminate
5
2
2 NOT PRESENT
5
2
3 NOT PRESENT
5
2
4 NOT PRESENT
5
2
5 Zone 2 heating maximum temperature setting
35 to + 82°C
82
if parameter 420 = 1
20 to + 45°C
45
if parameter 420 = 0
5
2
6 Zone 2 heating minimum temperature setting
35 to + 82°C
35
if parameter 420 = 1
20 to + 45°C
20
if parameter 420 = 0
5
3 DIAGNOSTICS
5
3
0
NOT PRESENT
5
3
1
NOT PRESENT
5
3
2
NOT PRESENT
5
3
3 Zone 2 set temperature
5
3
4 Zone 2 heat request
0=OFF
1=ON
5
3
5 Zone 2 Pump status
0=OFF
1=ON
5
4 ZONE DEVICE MANAGEMENT
5
4
0
NOT PRESENT
5
4
1
NOT PRESENT
5
4
2
NOT PRESENT
5
5 MULTIZONE
5
5
0
NOT PRESENT
5
5
1
NOT PRESENT
7 TEST & UTILITIES
7
0
0 Function test - Cleaning
turn the encoder to select the operating mode
t-- = funct. at Max heating power
t--
activation can also be obtained by
pressing the Reset button for 10
seconds. The function is deactivated
after 10 minutes or by pressing Reset
7 0
1
Bleed cycle
press Menu
8 PARAMETER FOR TECHNICAL ASSISTANCE
8
1 Entering access code
222 press the programming "+" button to
select 234 and press the m
eNu
button
8
2 BOILER
8
2
0
NOT PRESENT
8
2
1 Fan status
ON or OFF
8
2
2 Fan speed (x100) rpm
8
2
3
NOT PRESENT
8
2
4
NOT PRESENT
menu
sub
-menu
Par
amet
er
Description
value
default setting