45
settings - adjustment - problem identifi cation menus
menu
sub
-menu
P
a
rameter
Description
value
default setting
5
2
4
Compensation
from 0 to 20
20
if setting = 0, the temperature
taken from the ambient sensor
does not aff ect the calculation
of the setting. If setting = 20, the
temperature taken has maximum
infl uence on the setting.
5
2
5
Zone 2 heating MAXIMUM temperature
setting
from 35 to 85 °C
82
if parameter 520 = 1
from 20 to 45 °C
45
if parameter 520 = 0
5
2
6
Zone 2 heating MINIMUM temperature
setting
from 35 to 85 °C
35
if parameter 520 = 1
from 20 to 45 °C
25
if parameter 520 = 0
5
3
DIAGNOSTICS
5
3
4
Zone 2 heat request
0 = OFF
1 = ON
6
ZONE 3 PARAMETER
6
0
ZONE 3 TEMPERATURE SETTING
6
0
2
Heating fi xed temperature setting
“Heating fi xed temp”
from 35 to 82 °C
(high temperature - para. 420 =1)
70
Activated only with temperature
control and fi xed temperature (see
621)
from 20 to 45 °C
(high temperature - para. 420 =0)
20
6
2
ZONE 3 SETTING
6
2
0
Heating appliance temperature value
setting
0 = from 20 to 45°C
(low temper ature)
1 = from 35 to 85°C
(high temperature)
1
select in the appliance type base
6
2
1
Basic heating control type selection type
depending on the peripheral devices
connected
0 = fi xed fl ow temperature
1 = device On/Off
2 = NOT PRESENT
3 = external sensor only
4 = NOT PRESENT
1
To activate heating control, press
the AUTO button. The display
lights up the AUTO symbol
6
2
2
Slope
from 0_2 to 0_8
(low temperature)
from 1_0 to 3_5
1_5
(high temperature)
- see graph on page 42
If the external sensor is used, the boiler calculates the most suitable heating fl ow temperature taking the external temperature
and the type of appliance into account.
The type of curve must be chosen according to the type of appliance radiator and the heat losses present in the building.
6
2
3
Parallel curve shift Zone 2 Off set
from - 7 to + 7 (low temperature)
0
from - 14 to + 14 (high temperature)
To adapt the thermal curve to the appliance requirements, it is possible to perform a parallel shift of the curve in order to alter the
calculated fl ow temperature and therefore the ambient temperature.
By accessing this parameter or pressing the buttons 12 the curve can be shifted in a parallel manner as indicated in the fi gure
shown below.
The value is indicated on the display:
- from -7 to +7
(low temperature)
- from -14 to +14
(high temperature)
Each step represents a fl ow temperature increase/decrease of 1°C in relation to the
set-point value.
6
2
4
Compensation
from 0 to 20
20
if setting = 0, the temperature taken
from the ambient sensor does not
aff ect the calculation of the setting.
If setting = 20, the temperature
taken has maximum infl uence on
the setting.
6
2
5
Zone 3 heating MAXIMUM temperature
setting
from 35 to 85 °C
82
if parameter 620 = 1
from 20 to 45 °C
45
if parameter 620 = 0
6
2
6
Zone 3 heating MINIMUM temperature
setting
from 35 to 85 °C
35
if parameter 620 = 1
from 20 to 45 °C
25
if parameter 620 = 0