12 -
GB
L
N
230V
OUT 1
OUT 2
T
B
BUS
T
B
BUS
230V Z1
N L
Z2
BUS
T B
SE
TNK
SOL
TA1
FLOOR
TA2/
230V
230V 230V
230V
230V 230V
start-up
Warning!
Before performing any intervention, discon-
nect the power supply.
ELECTRICAL CONNECTIONS
For greater safety, ask a qualifi ed techni-
cian to perform a thorough check of the
electrical system.
The manufacturer shall not be responsi-
ble for any damage caused by the ab-
sence of a suitable earthing system or
by the malfunctioning of the electricity
mains supply. Ensure that the electrical
system can provide the maximum pow-
er required by the module (as indicated
on the data plate). Ensure that the wires
have a suitable cross-sectional area of at
least 1.5 mm
2
.
Proper connection to an effi
cient earthing
system is essential for ensuring safe op-
eration of the device.
The power supply cable must be con-
nected to a 230 V-50 Hz network, while
observing the L-N poles and ensuring
connection to earth.
H05 V2V2-F
Important!
The connection to the mains must be per-
manent (not using a plug) and equipped
with a dual-pole switch with a contact air
gap of at least 3 mm when open.
WARNING:
OBSERVE THE POLARITY MARKINGS OF THE BUS CONNECTION IN CASE OF MUL-
TIPLE POWER BOARDS.
Summary of Contents for Chafforeaux elco 3319130
Page 65: ...RU 65 8 2012 19 49 2014 RAEE 400 2 25...
Page 67: ...RU 67 1 2 ON L N 230V L N OUT 1 L N OUT 2 T B BUS T B BUS 1 2 3 1 2 2 230 BridgeNet 3...
Page 70: ...70 RU 1 2 ON 1 2 ON L N 230V OUT 1 OUT 2 T B BUS T B BUS 230 OUT1 OUT2...
Page 79: ...GR 79 8 2012 19 EU D Lgs 49 2014 400 m2 25 cm...
Page 86: ...86 GR Z1 Z2 BUS...
Page 89: ...89...
Page 90: ...90...
Page 91: ...91...