![Ariston AURES SLIM FLOW Manual Download Page 10](http://html.mh-extra.com/html/ariston/aures-slim-flow/aures-slim-flow_manual_2971888010.webp)
10
Unit Dimensions: Height 183mm Width 290mm Depth 108mm
Table 2
Power
kW Loaded
Heating Setting
Recomended
Cable Size
Recomended
Fuse Rating
220V 230V 240V
3.5kW
3.5
3.8
4.1
1.5+2.0 kW
2.5/4mm
2
20 amps
4.0kW
4.0
4.3
4.7
1.0+3.0 kW
2.5/4mm
2
20 amps
5.0kW
5.0
5.5
6.0
2.0+3.0 kW
4/6mm
2
25 amps
5.5kW
5.5
6.0
6.5
2.2+3.3 kW
4/6mm
2
25-32 amps
7.0kW
7.0
7.6
8.3
3.0+4.0 kW
6/10mm
2
40 amps
7.7kW
7.7
8.4
9.1
3.0+4.0 kW
6/10mm
2
40 amps
• operating water pressure 0.2-8 BAr (3-116 psi) • Water pressure operating power switch
• standard 1/2"Ø compression inlet connection • top-left and right cable entry • Bottom-left water entry
Close cover Steps
A
B
C