![Ariston AST 100 Installation, Commissioning And User Instructions Download Page 7](http://html1.mh-extra.com/html/ariston/ast-100/ast-100_installation-commissioning-and-user-instructions_2971060007.webp)
6
3.
TECHNICAL DATA
CONTROLLER
Type
AST100
Housing
PC-ABS & PMMA
Dimensions
173 x 110 x 46
Mounting
Wall (2 screws)
Operation
3 Push Buttons
Protection
IP20 / DIN 40050
Environmental Temperature
0 - 40°C
FUNCTIONS
Temperature Differential Control
Standard
Operating Hours Counter
Standard
Energy Monitor
Option
ELECTRICAL
Power Supply
210-240V
Electromechanical Relay
250V
Controller Mains Cable
1.0mm² 3 core heat resistant flex 3093y
Pump Cable (R1 and R2)
1.0mm² 3 core heat resistant flex 3093y
SENSORS
Collector Sensor
S1
Cylinder lower
S2
Cylinder upper
S3
Energy monitor (collector return)
S4