background image

3

 

USER’S MANUAL

The installation and first ignition of the boiler 
must be performed by qualified personnel in 
compliance with current national regulations 
regarding installation, and in conformity 
with any requirements established by local 
authorities and public health organisations. 
After the boiler has been installed, the installer 
must ensure that the end user receives the 
declaration of conformity and the operating 
manual, and should provide all necessary 
information as to how the boiler and the safety 
devices should be handled.

This appliance is designed to produce hot water for domestic use 
(combi version). 
It should be connected to a heating system and a distribution 
network for domestic hot water, both of which must be compatible 
with its performance and power levels. 
The use of the appliance for purposes other than those specified is 
strictly forbidden. The manufacturer cannot be held responsible for 
any damage caused by improper, incorrect and unreasonable use 
of the appliance or by the failure to comply with the instructions 
given in this manual. 
Installation, maintenance and all other interventions must be 
carried out in full conformity with the governing legal regulations 
and the instructions provided by the manufacturer.  Incorrect 
installation can harm persons, animals and possessions; the 
manufacturing company shall not be held responsible for any 
damage caused as a result. 
In the event of any maintenance or other structural work in the 
immediate vicinity of the ducts or flue gas exhaust devices and 
their accessories, switch the appliance off by switching the external 
bipolar switch to the “OFF” position and shutting off the gas valve. 
When the work has been completed, ask a qualified technician to 
check the efficiency of the ducting and the devices. 
If the boiler should be out of use for a prolonged period, it is 
recommended that the electrical power supply be disconnected 
and that the external gas cock be closed. If low temperatures are 
expected, the boiler and system pipe work should be drained in 
order to prevent frost damage.
Turn the boiler off and turn the external switch “OFF” to clean the 
exterior parts of the appliance. 
Do not allow children or inexperienced persons to use the 
appliance without supervision.

CE labelling

The CE mark guarantees that the appliance conforms to the 
following directives:

2009/142/CEE

  relating to gas appliances 

2004/108/CEE

  relating to electromagnetic compatibility

92/42/CEE

  relating to energy efficiency

2006/95/CEE

  relating to electrical safety
-  

2009/125/CE

 

Energy related Products 

-  

813/2013

  Commission regulation (EU)

Summary of Contents for 41-116-46

Page 1: ...CONDENSING WALL HUNG GAS BOILER Country of Destination GB IE CLAS HE R HOT WATER I HEATING I RENEWABLE I AIR CONDITIONING G C N 41 116 46 24 kW USER S MANUAL ...

Page 2: ... either by material or workmanship of the manufacturer This guarantee does not protect malfunction or damage arising from incorrect installation commissioning or maintenance procedures as laid out in the installation and servicing manual inefficient flue system poor or incorrect electricicty wrong gas supply or pressure tampering by inexperienced persons and any other cause not directly due to man...

Page 3: ...s and the instructions provided by the manufacturer Incorrect installation can harm persons animals and possessions the manufacturing company shall not be held responsible for any damage caused as a result In the event of any maintenance or other structural work in the immediate vicinity of the ducts or flue gas exhaust devices and their accessories switch the appliance off by switching the extern...

Page 4: ...rocution from live components Do not use insecticides solvents or aggressive detergents to clean the appliance Damage to plastic and painted parts Do not use the appliance for any use other than normal domestic use Damage to the appliance caused by operation overload Damage caused to objects treated inappropriately Do not allow children or inexperienced individuals to operate the appliance Damage ...

Page 5: ...lockout light 4 Button _ 5 Temperature regulation knob 6 Esc button 7 Menu OK button Programming key 8 Button 9 ON OFF button Green indicator ON OFF 10 Blue indicator burner ON 11 Green indicator Auto function 12 Auto button To activate Thermoregulation 5 3 2 1 4 9 10 11 8 7 6 12 ...

Page 6: ...ntral heating mode the flow temperature in anti freeze mode Adjusting the heating It is possible to set the temperature of the heating water by adjusting the knob 5 By placing the indicator somewhere between min and max A temperature may be obtained which varies from approximately 40 C to about 82 C Switching off the heating To switch off the heating mode turn the knob 5 to the position Or set the...

Page 7: ...n for 2 minutes After the two minutes of circulation fixed the boiler will check the following a if the flow temperature is 8 C the pump stops b if the flow temperature is between 4 and 8 C the pump will run for another two minutes c if the flow temperature is 4 C the burner will fire at mini mum power until the temperature reaches 33 C the bur ner will go off and the pump will continue to run for...

Page 8: ...N DESIGN Ariston Thermo UK Ltd Artisan Building Hillbottom Road High Wycombe Bucks HP124HJ Telephone 01494 418500 Technical Advice 0333 240 7777 Customer Service 0333 240 8777 ariston com uk 420010619800 0915 ...

Reviews: