USER’S MANUAL

Appliance shut-off conditions

The boiler is protected from malfunctions by means of internal 
checks performed by the electronic P.C.B., which stops the boiler 
from operating if necessary. In the event of the boiler being shut off 
in this manner, a code appears on the control panel display which 
refers to the type of shut-off and the reason behind it.
Two types of shut-off may occur:

Safety shut-off

This type of error is “volatile”, which means 
that the boiler starts up again automatically 
as soon as the problem which caused the 
shut-off is removed. The display will flash ”Err” 
and the error code.
As soon as the cause of the shut-off disappears, the boiler starts up 
again and continues to operate normally. 
While the boiler is shut off for safety reasons, it is possible to attempt 
to restore normal operation by switching the appliance off and on 
again using the ON/OFF button on the control panel.
If the boiler still indicates a safety shut-off, switch it off. Make sure 
the external electric switch is in the OFF position, close the gas tap 
and contact a qualified technician.

Operation shutdown

This type of error is “non volatile”, which means that it is not removed 
automatically. The display will flash 

Err

 and the error code

 

and the 

red led lights up “3” 

.

In this case the boiler does not restart automatically, but it may be 
reset by pressing the  

  button 

2

. If the problem manifests 

itself again after several attempts to reset the appliance, contact a 
qualified technician.

Display

Description

 

1 01

Overheating

5 01

No flame detection

1 03

Insufficient circulation

1 04
1 05
1 06
1 07
3 05

P.C.B error

3 06

P.C.B error

3 07

P.C.B error

IMPORTANT
IF  THIS  SHUTDOWN  OCCURS  FREQUENTLY,  CONTACT  AN 
AUTHORISED  SERVICE  CENTRE  FOR  ASSISTANCE.  FOR  SAFETY 
REASONS, THE  BOILER WILL  ALLOW  A  MAXIMUM  OF  5  RESET 
OPERATIONS  TO  TAKE  PLACE  IN  15  MINUTES  (INDIVIDUAL 
PRESSES OF THE 

 

BUTTON).

Operation shutdown error table

Anti-frost Device. 

The anti-frost function acts on the central heating flow temperature 
probe, independently from other settings, when the electrical sup-
ply is turned on.
If the primary circuit temperature falls below 8°C the pump will run 
for 2 minutes.
After the two minutes of circulation (fixed) the boiler will check the 
following:
a) if the flow temperature is > 8°C, the pump stops;
b) if the flow temperature is between 4 and 8°C, the pump will run 

for another two minutes;

c) if the flow temperature is < 4°C, the burner will fire at mini-

mum power until the temperature reaches 33°C, the bur-
ner will go off and the pump will continue to run for two  
minutes.

The anti-frost device activates only when (with the boiler operating 
correctly):
-  the boiler is electrically powered,
-  there is a supply of gas.

Auto button - Temperature adjustment activation

The AUTO function enables boiler operation to be adapted to 
environmental conditions and to the type of system it is installed on. 
Comfortable temperature is reached inside the room in the quickest 
way possible, without wasting money, energy or efficiency, while 
substantially reducing the amount of wear experienced by the 
components.

Your installer will advise you on the devices connectable to the 
boiler and will program according to the system.

In normal boilers the water temperature inside the heating elements 
is usually set to a high value (70-80°C), thereby ensuring effective 
heating during the few really cold winter days. It then becomes 
excessive on less cold days (of which there are many) more typical 
of the autumn and winter seasons. This leads to excessive room 
heating after the thermostat has been switched off, resulting in 
energy waste and uncomfortable conditions inside the room.
The AUTO function “takes control” of the boiler and selects the best 
operating regime based on environmental conditions, external 
devices connected to the boiler and the performance required. It 
constantly decides at which power level to operate based on the 
environmental conditions and the room temperature required.

Change of gas type 

Our boilers are designed to function either with Natural Gas 
(methane) or Propane. If you need to change from one gas to the 
other, one of our Authorised Service Centres must be contacted to 
convert the appliance.

Maintenance

Schedule an annual maintenance check-up for the boiler with a 
competent person.
Correct maintenance always results in savings in the cost of 
running the system.
Failure to arrange an annual service for the appliance will invalidate 
the second year and subsequent years of the manufacturers 
guarantee. 

Summary of Contents for 41-116-46

Page 1: ...CONDENSING WALL HUNG GAS BOILER Country of Destination GB IE CLAS HE R HOT WATER I HEATING I RENEWABLE I AIR CONDITIONING G C N 41 116 46 24 kW USER S MANUAL ...

Page 2: ... either by material or workmanship of the manufacturer This guarantee does not protect malfunction or damage arising from incorrect installation commissioning or maintenance procedures as laid out in the installation and servicing manual inefficient flue system poor or incorrect electricicty wrong gas supply or pressure tampering by inexperienced persons and any other cause not directly due to man...

Page 3: ...s and the instructions provided by the manufacturer Incorrect installation can harm persons animals and possessions the manufacturing company shall not be held responsible for any damage caused as a result In the event of any maintenance or other structural work in the immediate vicinity of the ducts or flue gas exhaust devices and their accessories switch the appliance off by switching the extern...

Page 4: ...rocution from live components Do not use insecticides solvents or aggressive detergents to clean the appliance Damage to plastic and painted parts Do not use the appliance for any use other than normal domestic use Damage to the appliance caused by operation overload Damage caused to objects treated inappropriately Do not allow children or inexperienced individuals to operate the appliance Damage ...

Page 5: ...lockout light 4 Button _ 5 Temperature regulation knob 6 Esc button 7 Menu OK button Programming key 8 Button 9 ON OFF button Green indicator ON OFF 10 Blue indicator burner ON 11 Green indicator Auto function 12 Auto button To activate Thermoregulation 5 3 2 1 4 9 10 11 8 7 6 12 ...

Page 6: ...ntral heating mode the flow temperature in anti freeze mode Adjusting the heating It is possible to set the temperature of the heating water by adjusting the knob 5 By placing the indicator somewhere between min and max A temperature may be obtained which varies from approximately 40 C to about 82 C Switching off the heating To switch off the heating mode turn the knob 5 to the position Or set the...

Page 7: ...n for 2 minutes After the two minutes of circulation fixed the boiler will check the following a if the flow temperature is 8 C the pump stops b if the flow temperature is between 4 and 8 C the pump will run for another two minutes c if the flow temperature is 4 C the burner will fire at mini mum power until the temperature reaches 33 C the bur ner will go off and the pump will continue to run for...