-- 48 --
bu09d12e2
5.1
MAINS SUPPLY
S
Connect the power supply lead using the appropriate fuse in conformance with
local regulations.
Power supply lead complies to Swedish electrical regulations.
LUD 320
3
~
50 Hz
3
~
50 Hz
3
~
50 Hz 3
~
60 Hz
3
~
60 Hz
3
~
60 Hz
3
~
60 Hz
Voltage V
230
400
500
208
230
460
475
Current A 100%
60%
27
37
16
21
13
15
30
38
27
34,5
13,5
17
13
16,5
Mains lead rating
4x10
4x4
4x4
4x10
4x10
4x4
4x4
Fuse, slow A
25
16
16
35
25
16
16
LUD 450
3
~
50 Hz
3
~
50 Hz
3
~
50 Hz 3
~
60 Hz
3
~
60 Hz
3
~
60 Hz
3
~
60 Hz
Voltage V
230
400
500
208
230
460
475
Current A 100%
40
24,5
18,5
45
41
20
19,5
60%
51
30,5
23
57,5
51,5
25
24,5
45%
55,5
34
25
62
56,5
27,5
26,5
Mains lead rating
4x10
4x4
4x4
4x10
4x10
4x4
4x4
Fuse, slow A
50
20
20
50
50
20
20
5.2
Termination resistance
The termination resistance must be connected to the ends of the CAN bus to prevent
communication problems.
The controller has a built--in terminator, but the power source and wire feed unit do
not.
The terminator should be fitted as follows depending on how the units are
connected:
1.
Controller connected to wire feed unit.
The termination resistance must be con-
nected to the rear of the power source.
(Already connected this way on delivery).
2.
Controller connected to power source.
The termination resistance
must be connected to the front
of the wire feed unit.