CO LINE WIRING CO Card REV2:
Before wiring the CO Lines, please refer to Figure 21, which shows you how to
connect the wires into the Terminal-Block Connector.
A.
Skin the insulation to expose a minimum of 10 mm of the inner cooper wire.
B.
Push backward the upper button of the Terminal-Block Connector.
C.
Insert the exposed cooper wire into the hole of the Terminal-Block Connector.
D.
After the exposed cooper wire has been inserted to the hole, release the upper
button of the Terminal-Block Connector, and make sure that the exposed cooper
wire is clamped tightly.
Figure 21. How to connect the wires into the Terminal-Block Connector
Summary of Contents for AV 32A
Page 13: ......
Page 20: ...A6MBUA MOTHER BOARD UNIT Figure 4 A6MBUA Mother Board Unit ...