Install the C-130
This chapter contains the step wise procedure to install the C-130 device.
Zero-Configuration of C-130 as Access Point
Zero-configuration is supported under the following conditions:
• The device is in AP mode with background scanning on and no SSID configured.
• A DNS entry wifi-security-server is set up on all the DNS servers. This entry should point to the IP address
of the server. By default, the AP looks for the DNS entry wifi-security-server.
• The AP is on a subnet that is DHCP enabled.
Important: If the device is placed on a network segment that is separated from the server by a firewall,
you must first open port 3851 for User Datagram Protocol (UDP) and Transport Control Protocol (TCP)
bidirectional traffic on that firewall. This port number is assigned to Arista Networks. Zero-configuration
cannot work if multiple devices are set up to connect to multiple servers. In this case, you must manually
configure the APs. See the Access Point Configuration Guide on our website at
https://www.arista.com/en/support/product-documentation
.
Take a configured AP; that is, ensure that a static IP is assigned to the device or the settings have been changed
for DHCP. Note down the MAC address and the IP address of the AP in a safe place before it is installed in a
hard-to-reach location. The MAC address of the AP is printed on a label at the bottom of the product.
The steps to install the device are as follows:
•
on page 11
•
on page 13
•
Connect Access Point to the Network
on page 14
Mount the C-130
The steps to mount the C-130 involve:
•
Mounting Instructions using the Standard Package Contents
on page 11
•
Mounting Instructions using the Silhouette/Interlude Bracket Mount
on page 13
•
Mounting Instructions using the Wall Mount Bracket
on page 13
Mounting Instructions using the Standard Package Contents
The mounting procedure can be divided into two parts:
1. Affixing the bracket to the T -grid: Use the mounting bracket to install the C-130 on the ceiling. Fix the
bracket to the T-grid and rotate the bracket so that it snaps on the T-grid.
The bracket is now parallel to an arm of the T-grid. Ensure that the bracket is properly snapped to the T-grid.
Refer to the images given below.
11