Chapter 2: Preparation
Electrostatic Discharge (ESD) Precautions
Quick Start Guide: 7500N Series Modular Switches
9
•
Torque reading nut driver (for DC power supplies)
•
#2 Phillips head screwdriver
•
Torque reading screwdriver using #2 Pozidriv or 1/4" flat bit (Needed for PWR-2700-DC-R)
Two-post and four-post rack mounts:
shows the rack components required for each of the
modular switches.
1
The accessory kit includes screws that fit many common equipment racks.
2
Rack nuts are only for racks with unthreaded, rack-post holes.
2.3
Electrostatic Discharge (ESD) Precautions
Observe these guidelines to avoid ESD damage when installing or servicing the switch.
•
Assemble or disassemble equipment only in a static-free work area.
•
Use a conductive work surfaces (such as an anti-static mat) to dissipate static charge.
•
Wear an ESD wrist strap to dissipate static charge accumulation.
•
Minimize handling of assemblies and components.
•
Keep replacement parts in their original static-free packaging.
•
Remove all plastic, foam, vinyl, paper, and other static-generating materials from the work area.
•
Use tools that do not create ESD.
Table 2-3 Rack component requirements
Switch
Rack or cabinet (standard 19" EIA)
Rack screws
1
Rack nuts
2
Notes
DCS-7504N
8
8
2-post installation
10
10
4-post installation
DCS-7508N
10
10
2-post installation
16
16
4-post installation
DCS-7512N
22
22
4-post installation
DCS-7516N
24
24
4-post installation