Cabling the Switch
This equipment must be grounded. Never defeat the ground conductor.
This unit requires overcurrent protection.
Installation de cet équipement doit être conformes aux codes électriques locaux et nationaux.
Si nécessaire, consulter les organismes de réglementation appropriés et des autorités de
contrôle pour assurer la conformité.
Lire toutes les instructions d'installation avant de brancher le système à la source
d'alimentation.
Cet équipement doit être mis à la terre. Ne jamais modifier le conducteur de terre.
Cet appareil requiert une protection contre les surintensités.
4.2.1
Connecting AC Power
Describes how to connect the AC power supply to the device.
The following AC power supplies are supported.
PWR-7010-AC
PWR-150-AC
Power requirements vary by switch. Refer to
Table 4: Switch Specifications (Power Draw)
for
information regarding your specific system.
displays the location of the power supplies on the rear panel of the switch.
Power Configurations
•
Non-redundant: Connect power to either of the two power supplies.
•
Redundant: Connect each AC power supply to a circuit that provides the required power.
Note:
To Power down the Switch, remove all power cords and wires from the power supplies.
Input Power and Power Supply redundancy is dependent on the actual system power draw.
For maximum Input Power redundancy, each power supply should be connected to its own
input overcurrent protection.
Power supplies use cables that comply with IEC-320 and have a C13 plug. The accessory kit provides
two IEC-320 C13 to C14 power cables.
4.2.2
Connecting DC Power
Describes how to connect the DC power supply to the device.
The following DC power supplies are supported.
PWR-7010-DC
PWR-100-DC
Power requirements vary by switch. Refer to
Table 4: Switch Specifications (Power Draw)
for
information regarding your specific system.
displays the location of the power supplies on the rear panel of the switch. There is a cover
over the DC supply terminals.
Important:
15