Limit Switches
For high dynamic response or high load applications, where the controller is pushed to get the best possible
speed and acceleration performance, it may be necessary to install physical limit switches since the digital
position count from the controller may not be accurate. In those cases the limit switch can be turned ON.
Alternatively, for safety application these limit switches can be used to stop the actuator from moving when
a guard door is open.
NOTE:
Disabling the limit switch will only disable the physical limit switch. The electronic limit based on the
actuator stroke will still be enabled to stop the actuator from moving if the position count is reached
electronically.
NOTE:
If the limit switches are used for safety application both the left and the right limit switch should be
connected together to a single actuator inhibit signal.
WARNING:
If the limit switch is enabled but the
physical switches are not installed correctly, then the
actuator will not move at all. Even the Jog and Servo
Center functionality will be disabled.
Analog Output Setting
Output range selection
The analog output setting can be changed based on
the application. The voltage ranges and the current
ranges can be set by picking the appropriate selection.
The available voltage options are 0 to 5 V, 0 to 10 V, ±
5 V and ± 10 V. The available current options are 0 to
10 mA, 0 to 20 mA, 0 to 24 mA and 4 - 24 mA.
NOTE:
Any combination of the voltage and current setting can be selected, except when 0 - 10 mA is
selected the voltage output is automatically set to 0 - 5 V.
Analog mode
While in edge mode the controller can be programmed to provide the position of the left edge, or right edge
or centerline position or the web width or the web coverage. The analog mode can be changed only if the
sensor sees both edges of the web. Selecting the appropriate analog mode button will enable the user to
accomplish the functionality.
NOTE:
When only one edge is seen by the sensor or when the sensor is in single edge mode, the analog
mode cannot be changed. The controller will automatically select the appropriate edge and by default will
provide the single edge position through the output.
Content subject to change without notice
SCU5: Sensor and Web Guide Controller User Manual v 3.6| Page 42