- 2 -
INTRODUCTION
This manual comprises the information concerning the operation, use and maintenance of VG Model
Gasification Type Wood Fired Hot Water Boilers. This manual alone is not sufficient for correct installation,
operation and use; installers, services and end user must obey the rules specified in current EN + local
norms, EC directives and local codes. This manual gives supplementary information and precautions.
Please keep this booklet near the appliance in a safe place in the boiler room for future reference.
Please read the manual very carefully in order to be able to operate your boiler safely and with high
efficiency for a long period.
Due to the continuous development in methods, design and manufacture, the contents of this
document may change at any time and without prior notice. Ar
ıkazan A.Ş. does not accept any responsibility
for errors or damage of any kind that is attributed to this publication.
WARNINGS
These safety guidelines should be read and fully understood before the first operation of the
system, to avoid incorrect usage that might lead to personal injury or damage to the system.
This boiler must be installed in accordance with the local and international rules in force, only in a
well ventilated and frost free spaces, indoor but other then living areas.
Do not open any part of the boiler while it is running. Electrical connection must be cut off before
any cleaning, service etc. processes.
All installation, assembly and maintenance, repair, replacement of components work must be
carried out exclusively by fully trained, professionally qualified personnel and must conform with this manual
and the local codes and requirements of the authority having jurisdiction, or in the absence of such
requirements, apply to the EEC directives and European norms (EN).
If the boiler is not used for the purposes other then specified in this booklet and incorrect
installation, commissioning and use, can cause a fire or explosion which may result property damage,
personnel injury, or loss of life.
Boiler is designed for hot water operation only (max 90
⁰
C) and the system pressure must be
according to the limited operating pressure specified on the boiler name plate and in this booklet. Heat
transfer medium is water.
Boilers must be fired by dry wood log
(humidity 15 …. 20 %) fuels specified in this manual. Using
wood logs with humidity more then %20 might cause tar creation and damages that will cause the boiler out
of warranty.
This is a B
23
appliance so the flue gases must be connected to an adequate draught chimney,
without any flue gas leakage to the boiler room.
It is essential that an appropriate pump is fitted in the circulation system which must be kept in
operation at all the times when the boiler in use.
The filling and make up water must be according to the specifications given in this manual. Long
term water treatment is essential to the economic operation and life of both new and refurbished heating
systems.
Never obstruct the ventilation openings to the boiler room for a safe and efficient operation. An
adequate air supply for combustion and ventilation must be provided at all times.
Boilers must not be installed in areas where inflammable vapors and materials are likely to
present. To avoid damage to the boilers, contamination of the combustion air by high levels of dust or
halogenated hydrocarbons (e.g. Solvents, spray can propellants, cleaning agents, adhesives, ect.) must be
avoided. The humidity level must not be high in boiler rooms.
The boiler room must not be used for other purposes and must not have an open connection to
the other closed living areas. Connection door must be air tight, fire resistant and self closing.
All the control devices must be functional and operating with in the limits specified at all the time.
If any of them is null functioning do not operate the system and call a qualified service.