Aria QBV100 Owner'S Manual Download Page 3

 

3 CONGLOMKB .COM

Please contact 

[email protected]

 or 

1-877-333-0098

 for further assistance .

ENGLISH

Warranty

ONE YEAR LIMITED WARRANTY

A thorough inspection must be made before installation and any damage must be promptly reported . We will not be liable for failures or 
damage that could have been discovered or avoided by proper inspection and testing prior to installation .

Conglom Inc . warrants this product to be free from defects in materials or workmanship for one (1) year from the date of purchase . Proof of 
purchase (original sales receipt) from the original consumer purchaser must be made available to Conglom Inc . for all warranty claims .  

This  warranty  is  non-transferable  and  shall  be  voided  if  the  unit  is  removed  from  its  initial  installation  or  if  it  is  not  installed  following 

the manufacturer’s instructions . It does not apply in the event of product damage due to the use of other than genuine Conglom Inc . 

replacement  parts,  (Replacement  parts  may  be  obtained  by  e-mail  at 

[email protected]

 or by calling 

1-877-333-0098

 between 

8:30 am - 5:00 pm EST) installation error, abuse, misuse or improper care and maintenance (whether performed by a plumber, contractor, 

service provider or member of the purchaser’s household) . The warranty excludes damage due to aggressive air or water conditions, harsh 
or abrasive cleaners and/or materials . 

Under no circumstance shall we be held liable for personal injury or property damage resulting from improper installation or use of this 
product . We will not be held liable for inconvenience caused by loss of use of this product, costs incurred for labour or materials, removal 
and installation of replacement units, or any other incidental or consequential damages . Costs relating to obtaining access for repair or 
replacement are the responsibility of the user . 

Our obligation shall be limited to the repair or replacement of a unit (at our discretion) that may prove, by our sole examination, to be defective 
under normal use and service during the warranty period . 

Any failure of this product that is not traceable to a defect in material or workmanship is not covered by this warranty. These non-warrantable 

items include, but are not limited to: 

 

-

Improper installation not in accordance with manufacturer’s instructions .

 

-

Dents and/or scratches incurred during shipping, handling, or installation . 

 

- Change in colour or finish due to chemical usage.

 

-

Damage caused by failure to follow care and cleaning guidelines, including damage caused by the use of abrasive cleaners .

 

-

Alterations made to the unit by the purchaser or installer .

 

- Damage caused by accidental impact, fire, flood, freezing, and normal wear.

 

- Bends and warping caused by forced connections, over-tightened fittings, and inadequate support during installation.

This warranty does not extend to commercial and institutional installation or use .

WARRANTY CLAIM PROCEDURE

If a claimable defect occurs or replacement parts are needed, please contact our customer service team at 

[email protected]

 or 

1-877-333-0098

 (Service available in English and French, Monday - Friday from 8:30 am - 5 pm, EST).

Before you make your call, please ensure that you have:

 

-

Model number or description .

 

-

Proof of sale .

 

-

Details regarding the defect and/or part number . 

 

-

Name(s) and address(es) of the owner and/or installer .

Summary of Contents for QBV100

Page 1: ...VENTILADOR ULTRA SILENCIOSO PARA CUARTO DE BA O PLEASE READ AND SAVE THESE INSTRUCTIONS INSTALLER PLEASE LEAVE THIS GUIDE WITH THE HOME OWNER LISEZ ET CONSERVEZ CES INSTRUCTIONS INSTALLATEUR LAISSEZ...

Page 2: ...ciation NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage elect...

Page 3: ...ed by loss of use of this product costs incurred for labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining acce...

Page 4: ...l Safety goggles Drywall saw Pry bar Wood screws Respiratory mask Cable clamp Flexible duct connector Duct adapter For best performance use 4 round metal ducting Other ducting is acceptable but may im...

Page 5: ...mage and or missing parts immediately to our customer service team at cs conglomkb com or 1 877 333 0098 Service available in English and French Monday Friday from 8 30 am 5 00 pm EST Please do not di...

Page 6: ...BV100 6 ENGLISH Pre Installation continued TYPICAL INSTALLATION Roof Cap Wall Cap Elbows Aluminum Foil Tape Power Cable Insulation Ventilation Fan Round or Flexible Duct Connector Not Included or Fig...

Page 7: ...ate so it can be enlarged to fit the new fan if required Check to ensure the joist arrow indicated on the template is oriented correctly It should be pointing towards the ceiling joist Mark the center...

Page 8: ...tion fan is properly grounded 2 Failure to follow electrical requirements may result in a fire 3 A fuse in the neutral or grounding circuit could result in electrical shock 4 If the hot cold water pip...

Page 9: ...while it is energized will result in death or serious injury DANGER All electrical wiring must be properly installed insulated and grounded Improper insulation and grounding will result in deadly elec...

Page 10: ...aker or the power switch on the junction box before installing this unit Touching circuitry inside the ventilation fan while it is energized will result in death or serious injury NOTE Ensure your fan...

Page 11: ...ent ways to secure the housing to your ceiling joists both conventional and I joist Choose the method most appropriate to your ceiling construction as shown in figures 17 through 19 Joist Profiles Rei...

Page 12: ...ury to persons Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service discon...

Page 13: ...the fan has been secured properly Tighten into position if necessary Check that the motor is secured in place If not then tighten the motor in place Check that the fan is not damaged If so replace th...

Page 14: ...r Power W 28 Voltage Frenquency 120 VAC 60Hz Housing Dimensions 9 x 9 x 5 3 4 22 9 cm x 22 9 cm x 14 6 cm Grille Dimensions 11 13 16 11 7 16 30 cm x 29 1 cm Net Weight Kg 2 83 WIRING DIAGRAM Black Bla...

Page 15: ...ct our customer service team at cs conglomkb com or 1 877 333 0098 8 30 am 5 pm EST Monday Friday Identify the required part s and have the part number s ready A B C D E F G H Part Description Code Qu...

Page 16: ...conglomkb com service available in English and French Monday Friday from 8 30 am 5 pm EST service disponible en anglais et fran ais du lundi au vendredi 8h30 17h H N E servicio disponible en ingl s y...

Reviews: