Aria QBV100 Owner'S Manual Download Page 2

QBV100 2

 

ENGLISH

Table of Contents

Safety Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Warranty

One Year Limited Warranty  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Warranty Claim Procedure   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

Pre-Installation

Tools/Materials Required   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Package Contents    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5
Typical Installation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

Installation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

 

Care and Cleaning   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Troubleshooting   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Specifications 

Wiring Diagram    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 14
External Diagram of Fan Unit   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 14

Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

MANUEL DE L’UTILISATEUR   . . . . . . . . . . . . . . . . . . . . . . . . . . 16
MANUAL DEL USARIO  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Safety Information

 

WARNING:

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1 . 

Use this unit only in the manner intended by the manufacturer . If you 
have questions, contact the manufacturer .

2 . 

Before servicing or cleaning unit, switch power off at service panel 
and lock the service disconnecting means to prevent power from 
being switched on accidentally . When the service disconnecting 
means cannot be locked, securely fasten a prominent warning device, 
such as a tag, to the service panel .

3 . 

Installation work and electrical wiring must be done by a qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-rated construction codes and standards.

4 . 

Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to prevent 

back drafting . Follow the heating equipment manufacturer’s guideline 
and safety standards such as those published by the National Fire 
Protection Association (NFPA), and the American Society for Heating, 
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local 
code authorities .

5 . 

When cutting or drilling into wall or ceiling, do not damage electrical 
wiring and other hidden utilities .

6 . 

Ducted fans must always be vented to the outdoors .

7 . 

If this unit is to be installed over a tub or shower, it must be marked 
as appropriate for the application and be connected to a GFCI (Ground 
Fault Circuit Interrupter) – protected branch circuit .

8 . 

This unit must be grounded .

9 . 

Always unplug or disconnect the appliance from the power supply 
before servicing .

10 . 

To reduce the risk of fire or electric shock, do not use this fan with any 

solid-state speed control device.

11 .  Do not install ventilation fan in a ceiling thermally insulated to a value 

greater than R40 .

12 .  Use an ON/OFF switch to operate this ventilation fan . Use of speed 

controls may damage the motor .

13 .  DO NOT INSTALL IN A WALL .

WARNING:

 

The unit has sharp edges . Always wear safety 

gloves during installation, cleaning, or servicing .

CAUTION!

For general ventilating use only . Do not use to exhaust hazardous or 
explosive materials and vapors .

DO NOT install this unit onto an acoustic ceiling panel .

This product is designed for installation in ceilings up to a 12/12 pitch (45 
degree angle) . Duct connector must point up . 

To avoid motor bearing damage and noisy, unbalanced impellers, keep 
drywall spray and construction dust away from power unit .

Please read specification label on product for further information and 

requirements .

COOKING AREA

Do not install above or inside this area

Cooking

Equipment

45˚

45˚

Floor

Summary of Contents for QBV100

Page 1: ...VENTILADOR ULTRA SILENCIOSO PARA CUARTO DE BA O PLEASE READ AND SAVE THESE INSTRUCTIONS INSTALLER PLEASE LEAVE THIS GUIDE WITH THE HOME OWNER LISEZ ET CONSERVEZ CES INSTRUCTIONS INSTALLATEUR LAISSEZ...

Page 2: ...ciation NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage elect...

Page 3: ...ed by loss of use of this product costs incurred for labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining acce...

Page 4: ...l Safety goggles Drywall saw Pry bar Wood screws Respiratory mask Cable clamp Flexible duct connector Duct adapter For best performance use 4 round metal ducting Other ducting is acceptable but may im...

Page 5: ...mage and or missing parts immediately to our customer service team at cs conglomkb com or 1 877 333 0098 Service available in English and French Monday Friday from 8 30 am 5 00 pm EST Please do not di...

Page 6: ...BV100 6 ENGLISH Pre Installation continued TYPICAL INSTALLATION Roof Cap Wall Cap Elbows Aluminum Foil Tape Power Cable Insulation Ventilation Fan Round or Flexible Duct Connector Not Included or Fig...

Page 7: ...ate so it can be enlarged to fit the new fan if required Check to ensure the joist arrow indicated on the template is oriented correctly It should be pointing towards the ceiling joist Mark the center...

Page 8: ...tion fan is properly grounded 2 Failure to follow electrical requirements may result in a fire 3 A fuse in the neutral or grounding circuit could result in electrical shock 4 If the hot cold water pip...

Page 9: ...while it is energized will result in death or serious injury DANGER All electrical wiring must be properly installed insulated and grounded Improper insulation and grounding will result in deadly elec...

Page 10: ...aker or the power switch on the junction box before installing this unit Touching circuitry inside the ventilation fan while it is energized will result in death or serious injury NOTE Ensure your fan...

Page 11: ...ent ways to secure the housing to your ceiling joists both conventional and I joist Choose the method most appropriate to your ceiling construction as shown in figures 17 through 19 Joist Profiles Rei...

Page 12: ...ury to persons Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service discon...

Page 13: ...the fan has been secured properly Tighten into position if necessary Check that the motor is secured in place If not then tighten the motor in place Check that the fan is not damaged If so replace th...

Page 14: ...r Power W 28 Voltage Frenquency 120 VAC 60Hz Housing Dimensions 9 x 9 x 5 3 4 22 9 cm x 22 9 cm x 14 6 cm Grille Dimensions 11 13 16 11 7 16 30 cm x 29 1 cm Net Weight Kg 2 83 WIRING DIAGRAM Black Bla...

Page 15: ...ct our customer service team at cs conglomkb com or 1 877 333 0098 8 30 am 5 pm EST Monday Friday Identify the required part s and have the part number s ready A B C D E F G H Part Description Code Qu...

Page 16: ...conglomkb com service available in English and French Monday Friday from 8 30 am 5 pm EST service disponible en anglais et fran ais du lundi au vendredi 8h30 17h H N E servicio disponible en ingl s y...

Reviews: