ARI ELIPTIX  R-30 Series Installation Operation & Maintenance Download Page 4

R-30 Y 

 

 

 

 

 

 

 

 

 

1.  SAFETY INSTRUCTIONS 

 
General 

1.

 

A.R.I. products always operate as components in a larger system. It is essential for the system designers, installers, 
operators and maintenance personnel to comply with all the relevant safety standards. 

2.

 

Installation,  operation  or  maintenance  of  the  product  should  be  done  only  by  qualified  workers,  technicians 
and/or contractors using only good engineering practices, complying with and observing all conventional safety 
instructions in order to minimize risk and/or danger and/or hazard to workers, the public or to property in the 
vicinity in accordance with all relevant local standards. 

3.

 

Extra  safety  considerations  should  be  taken  with  hot  and  hazardous  liquids  or  in  hazardous  environments' 
applications to avoid bodily/physical harm and damage to public or private property. 

4.

 

All individuals installing operating and/or handling the products including all workers should at all times adhere 
to  the  occupational  safety  and  health  (OSH)  instructions  and  wear  safety  helmets,  goggles,  gloves,  and  any 
other personal safety equipment required by the local standards and regulations. 

5.

 

Use only appropriate standard tools and equipment operated by qualified operators when installing, operating 
and maintaining the product. 

6.

 

Prior  to  installation,  operation,  maintenance  or  any  other  type  of  action  carried  out  on  the  product,  read 
carefully the safety, installation and operation instructions of the product. 

7.

 

Please note: 

-

 

Pressurized fluid and/or gas may be discharged from the product without prior warning. Make sure that all products' 

outlet ports are not directed toward electrical elements (pumps) or people. 

8.

 

Always open and close valves slowly and gradually. 

9.

 

Please note that the maximum working pressure indicated at the product’s specifications table doesn't include 
pressure  changes  caused  by  water  hammer  and  pressure  surge  effects.  Use  the  product  only  according  to  its 
designated pressure rate specifications. 

10.

 

Use the product only for its intended use as designed by A.R.I. Any misuse of the product may lead to undesired 
damages and may affect your warranty coverage. Please consult with A.R.I. prior to any non-regular use of this 
product and make no change or modification to the product without a prior written consent to be provided by 
A.R.I. at A.R.I.'s sole discretion. 

11.

 

Please note that A.R.I. shall NOT assume any liability with respect to any damage losses and/or expenses caused 
to any person and/or property whatsoever unless the product has been duly installed and thereafter maintained 
in  strict  compliance  with  its  designated  maintenance  Instructions  and/or  any  other  installation  and  operation 
manuals provided by A.R.I. for the product and/or applicable ordinances and/or codes. 

 

Handling 

1.

 

Shipping and handling the product must be done in a safe and stable manner and in accordance with the relevant 
standards and regulations. 

2.

 

Storage should be in the original delivery crates or cases. Storage should be off the ground in a clean, dry indoor 
area. 

3.

 

For lifting and positioning the product, use only approved lifting equipment operated by authorized employees 
and contractors. 

4.

 

Prior to the installation visually verify that the product was not damaged during shipment to the installation site. 

Summary of Contents for ELIPTIX R-30 Series

Page 1: ...liptic shaped diaphragm that integrates well with a wide variety of regulating control pilots solenoids and control accessories They are compatibility designed for water level control flow control ele...

Page 2: ...ol Valve 9 2 4 Initial Set up The ON OFF Application 10 3 OPERATION INSTRUCTIONS 11 4 MAINTENANCE 12 4 1 Periodic Inspection 12 4 2 Storing the valve 12 5 TROUBLESHOOTING 13 6 DISMANTLING AND ASSEMBLI...

Page 3: ...ever whether caused by accessing and or relying upon this Disclaimer and or in any document enclosed hereto including without limitation any links procedures or materials A R I shall NOT assume any li...

Page 4: ...iorwarning Make surethatallproducts outlet ports arenotdirectedtowardelectricalelements pumps orpeople 8 Always open and close valves slowly and gradually 9 Please note that the maximum working pressu...

Page 5: ...lations set for handling this type of fluid 3 Before disconnecting the product from the system and before releasing the residual pressure do NOT loosen or unscrew the product bolts removeanyprotection...

Page 6: ...ns 2 Make sure that all the tools ladders lifting devices etc used during the maintenance procedures are taken away from the product area and stored 3 Remove grease and fat material residues in order...

Page 7: ...2 Before installing the valve flush the pipeline to remove scale dirt and other particles that might affect the valve performance 3 Carefully remove the valve from the shipping package Unload all valv...

Page 8: ...tion valves upstream and downstream of the control valve 8 Y Strainer upstream of the control valve 9 3 Close the outlet 2 way ball valve 2A 4 Turn on the water supply to the valve 5 Check for leaks t...

Page 9: ...5 Gradually open the downstream isolation valve 8A 6 For automatic operation of the level control valve open the 2 way ball valves 2 and 2A 7 To manually close the valve close the outlet 2 way ball v...

Page 10: ...reservoir water level rises back to the pre set level the vertical float 5B floats with it As the float reach the upper stopper 5D the float valve 5C closes water from the upstream 2 way ball valve 2...

Page 11: ...the valve close the outlet 2 way ball valve 2A and make sure that the inlet 2 way ball valve 2 is open 3 To manually open the valve close the inlet 2 way ball valve 2 and make sure that the outlet 2...

Page 12: ...lly inspect the valve s diaphragm for any tears 2 Every 12 months inspect the valve s operation and clean the Finger Filter 3 Check the downstream pressure adjust if required 4 2 Storing the valve It...

Page 13: ...r stopper 5E Valve does not close 1 The inlet 2 way ball valve 2 is closed 1 Check the Inlet 2 way ball valve position 2 1 Open the 2 way Inlet ball valve 2 2 The diaphragm is damaged 2 Check the Diap...

Page 14: ...ing at the other 24 mm spanner open at one end and ring at the other 2 Release Pressure Make sure that the water supply to the valve is switched off release any residual pressure and isolate the valve...

Page 15: ...Disassembling the valve 1 Using a 24mm spanner release the 4 bolts of the valve s bonnet in a diagonal manner A D 2 Un screw the bonnet s bolts E F and remove the bonnet from the valve s body G H 1 1...

Page 16: ...R 30 Y 3 Remove the valve s spring I J 4 Remove the valve s diaphragm K L 3 3 4 4...

Page 17: ...Cleaning the Finger Filter 1 Disassemble and clean the finger filter using a 20mm spanner release the upstream 2 way manual valve A B Then using a 19mm spanner release the finger filter and clean it C...

Page 18: ...d tightened in all directions parallel to the valve s body 6 6 Reassembling the Control loop 1 Make sure that all the control loop components are in good condition and clean 2 Clean the control tubing...

Page 19: ...R 30 Y 7 DIMENSIONAL DRAWING...

Page 20: ...le nor does this warranty extended to any consequential or incidental damages or expenses of any kind or nature regardless of the nature thereof including without limitation injury to persons or prope...