2.  Check the position of the float inside the tank; it may have shifted during the move.  If it is not positioned 

correctly, reposition it before using it. 

 

 

 
 
 
 

3.  Then, reposition the tank. 

 

OPERATING INSTRUCTIONS 

 

APPLIANCE START-UP 

Place the product on a flat and stable heat-resistant surface, at least 1 metre away from flammable or heat-sensitive 
materials and 50 cm away from walls or other obstructions. 
Make sure the water tank is in the correct position.  
Connect the power cord to a suitable electric socket (220-240V/50Hz).  
Power the unit on with the ON/OFF button on the control panel. 

The dehumidifier is designed to operate at room temperature 

from + 5 °C to + 35 °C

If it is operated at low temperatures, ice may form on the evaporator, degrading its operation.  
When this happens, the dehumidifier goes into defrost mode. The compressor stops, but the fan continues running. 

We recommend not using the dehumidifier in room temperatures lower than 5 °C. 

 

OPERATING PRECAUTIONS

 

The appliance will only start operating if the humidity level in the room is above the set value. 

The dehumidifier will continue to operate until the set humidity level has been reached, 

with the

 

exception of 

interruptions caused by a full tank.

 In this case, empty and reinstall the tank: the dehumidifier will now start running 

again. 

 
WARNING: 
After each interruption of its operation, at least 3 minutes must pass before the dehumidifier starts up again: 
this delay prevents the compressor being damaged.   
If, on the other hand, the set humidity percentage is higher than the level currently found in the room, the 
dehumidifier will not start. 

If, after following the start-up instructions, 

the dehumidifier does not start 

or stops for no reason, make sure the plug 

and power cord are in good working order. After doing so, wait for 10 minutes and then restart the appliance. 
If the dehumidifier still does not start after 10 minutes, or if either the power cord or plug are damaged, switch off the 
appliance and contact an after-sales service centre. 

 
WARNING: 
When the dehumidifier is running, the compressor produces heat and the appliance emits warm air into the 
room. The room temperature will therefore tend to increase. This is completely normal. 
 

TURNING THE DEHUMIDIFIER OFF

 

To turn the dehumidifier off, press the ON/OFF button. This shuts off power to the unit. 
Unplug the appliance if you do not intend to use it for some time. 

 
 
 

Float 

Incorrect 

position 

Correct 
position 

Summary of Contents for PLATINUM 21

Page 1: ...ad the instructions carefully before operating or servicing the dehumidifier Observe all the safety instructions failure to observe the instructions may lead to accidents and or damage Keep these inst...

Page 2: ...ds involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Make sure the plug is inserted fully Do not use multiple adapters...

Page 3: ...midification efficiency Do not insert objects or sharp instruments into the air outlet grille Do not cover the air intake and outlet grilles in any way WARNING In the event of an anomaly switch the ap...

Page 4: ...k are correctly positioned 1 Remove the tank using both hands and following the direction of the arrow 1 CONTROL PANEL 2 DEHUMIDIFIED AIR OUTLET 3 CONTINUOUS CONDENSATION DRAINAGE HOLE COVER 4 AIR INT...

Page 5: ...l the set humidity level has been reached with the exception of interruptions caused by a full tank In this case empty and reinstall the tank the dehumidifier will now start running again WARNING Afte...

Page 6: ...CONTINUOUS CONDENSATION DRAINAGE You can fit a PVC hose with an internal diameter of 14 mm and length of 1 3 1 5m not included to drain the tank continuously Turn off the appliance and remove the plu...

Page 7: ...select to make the deflector swing continuously to optimize the airflow around the room or decide where to fasten the flap fixed angle LED FILTER CLEAN LED THE FILTER CLEAN LED will turn on to indica...

Page 8: ...leaning it to prevent electric shock and malfunction Warning Do not wet the appliance or immerse it in water otherwise electric shocks may occur Use a damp and soft cloth to clean the exterior surface...

Page 9: ...the top 2 Remove the filter by pulling the top towards you Clean the filter with a vacuum cleaner or wash it with clean water at no more than 40 C DO NOT USE ALCOHOL BENZENE OR OTHER AGGRESSIVE PRODUC...

Page 10: ...filter is full of dust The doors and windows are open If the unit is running with a temperature between 5 and 15 C the unit will pause for automatic defrosting The compressor will pause for short peri...

Page 11: ...at the end of its life cycle We call your attention to the crucial role played by the consumer in the re use recycling and other forms of recovery of such waste The appliance must be scrapped by a sor...

Reviews: