OPERATING INSTRUCTIONS

 

ASSEMBLING THE PARTS PROVIDED

 

 

Place the plastic support  

 

                      

 

 
 

Place the RGB LED integrated nebuliser into the space 

provided by the plastic support (previously positioned 

inside the lamp).  

 

See picture 8 above for the correct assembly procedure.  

 

 

inside the lamp

  

 

           

      

                    

                   

 

 

HOW THE APPLIANCE WORKS

 

  Fill the water tank with clean water and if desired, a few drops of essential oil ensuring that the nebuliser 

sensor is completely covered. Do not exceed the maximum water level as indicated by the silver marker 
found on the plastic support.  

  Use clean water every time the appliance is used in order to guarantee a longer life-span and increased 

effectiveness of the nebuliser.   

  When using distilled water, add salt in order to ensure sufficient electrolytes are present in the water for 

the ceramic disc to work effectively.   

  Attach the power cord to the nebuliser cord which is found at the rear of the appliance. 

 

Insert the power cord into an electric socket ensuring that the mains voltage is matches the voltage 
required by the product.  

 

  After a short while the appliance will begin to produce a cloud of cold mist which is dispersed into the 

surroundings. 

 

The mist is illuminated by the 12 RGB LED integrated nebuliser (6 red and 6 blue) which produces an 
array of continually fading and changing colours. 

 

 

WHAT TO DO IF THE APPLIANCE DOES NOT WORK

 

 

If after a few minutes the appliance fails to produce 

mist, the water level in the tank has more than likely 

fallen below the required minimum.  

 

 

 

If the appliance fails to produce mist and the LED light 

switches off, there may be a problem with the mains 

supply.  

 

 

If the appliance produces spurts of water rather than 

mist, the water in the tank is dirty.  

 

 

After approximately 3000 hours of operation the 

amount of mist produced by the appliance may 

decrease.  

 

 

 

 

 

 

Add sufficient water to completely cover the 

nebuliser sensor.  

 

Ensure the nebuliser cord is not covering the 

ceramic dish as this may impede mist production.  

 

 

Ensure the plug is correctly inserted into the 

socket.  

 

 

 

Unplug the appliance from the mains supply and 

replace the dirty water with clean tap water.  

 

 

Replace the ceramic disc.  

Purchase a replacement ceramic disc and 

turnkey necessary to carry out maintenance 

operations from an authorised dealer only. 

Carefully follow the instructions detailed below. 

 

 

 

Summary of Contents for Aiko

Page 1: ...of together with household waste but must be delivered to appropriate separate waste disposal plants or to dealers that provide similar service Separate waste disposal of electrical and electronic appliances prevents possible negative effects on the environment and human health resulting from inadequate disposal and also allows for recovering and recycling the materials comprising the appliances t...

Page 2: ...s may hamper its efficient operation Do not operate the appliance on unstable surfaces as the water flowing out of the appliance may wet the floor or cause malfunctions Do not place the appliance on a high or sloping surface as it may fall as a result of vibrations or accidental knocks Placing the appliance on a sloping surface may cause the humidifier s water level control device to malfunction t...

Page 3: ...ow the recommended level This avoids damage to the ceramic disc whilst warning the user to add more water DESCRIPTION OF PARTS 1 Frosted glass lamp with bamboo support containing the nebuliser humidifier 2 Plastic support for the nebuliser to be placed inside the lamp See picture 5 3 12 RGB LED nebulizer Emits an array of fading and changing colours 4 Water level control device water level must co...

Page 4: ... short while the appliance will begin to produce a cloud of cold mist which is dispersed into the surroundings The mist is illuminated by the 12 RGB LED integrated nebuliser 6 red and 6 blue which produces an array of continually fading and changing colours WHAT TO DO IF THE APPLIANCE DOES NOT WORK If after a few minutes the appliance fails to produce mist the water level in the tank has more than...

Page 5: ... the appliance to malfunction HOW TO REPLACE THE CERAMIC DISC 1 Unplug the appliance from the mains supply and empty the contents of the water tank 2 Dry the mist production aperture thoroughly as the disc to be replaced is located here 3 Insert the turnkey into the protection mechanism and turn anticlockwise 4 Remove the protection mechanism and take out the worn disc 5 Remove the protective rubb...

Reviews: