![Argo AER507SC Technical & Service Manual Download Page 9](http://html1.mh-extra.com/html/argo/aer507sc/aer507sc_technical-and-service-manual_2967459009.webp)
6
Indoor Unit AWR509CL
Outdoor Unit AER509SCL
Power Source 220–240V ~ 50Hz
Voltage rating 220/230/240 V
Performance Cooling
Capacity kW 2.60 / 2.60 / 2.65
BTU/h 8,900 / 8,900 / 9,000
Air circulation (High) m
3
/h 470
Moisture removal (High) Liters/h 1.1
Electrical Rating Cooling
Available voltage range V 198 ~ 264
Running amperes A 4.2 / 4.1 / 4.0
Power input W 910 / 920 / 940
Power factor % 98 / 98 / 98
C.O.P. W/W 2.9 / 2.8 / 2.8
Compressor locked rotor amperes A 19 / 20 / 21
Features
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit Wireless remote control unit
Timer ON/OFF 24 hours & Daily program,1-hour OFF
Fan speeds Indoor / Outdoor 3 and Auto / Auto (Hi,Me,Lo)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable, Anti-Mold
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R407C / 760
Refrigerant control Capillary tube
Operation sound Indoor : Hi / Me / Lo dB-A 38 / 33 / 31
Outdoor : Hi dB-A 46
Refrigerant tubing connections Flare type
Max. allowable tubing length at shipment m 7.5
Refrigerant Narrow tube mm (in.) 6.35(1/4)
tube diameter Wide tube mm (in.) 9.52(3/8)
Refrigerant tube kit / Accessories Optional / Air Clean Filter
Dimensions & Weight Indoor Unit Outdoor Unit
Unit dimensions Height mm 270 525
Width mm 805 790
Depth mm 177 220
Package dimensions Height mm 243 585
Width mm 855 865
Depth mm 332 320
Weight Net kg 8.0 33.0
Shipping kg 10.0 35.5
Shipping volume m
3
0.07 0.16
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are:
Cooling : Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.