![Argo AER507SC Technical & Service Manual Download Page 20](http://html1.mh-extra.com/html/argo/aer507sc/aer507sc_technical-and-service-manual_2967459020.webp)
2-3. Other Component Specifications
17
Thermistor (Coil sensor TH1)
PCB-41E-S14 or PBC – 41E – S4
Resistance k
Ω
– 20°C 40.1± 5% 20°C 6.5± 5%
– 10°C 24.4± 5% 30°C 4.4± 5%
0°C 15.3± 5% 40°C 3.0± 5%
10°C 9.9± 5% 50°C 2.1± 5%
Power Relay (PR)
G7L-2A-TUB
Coil rating
AC 200 – 240V, 50/60Hz
Coil resistance
Ω
(at 23°C)
21 ± 15%
Contact rating
AC 220V, 25A
Transformer (TR2)
ATR-J65
Rating Primary
AC 230V, 50Hz
Secondary
19V, 0.315A
Capacity
6VA
Coil resistance
Ω
(at 22°C)
Primary (WHT – WHT): 455 ± 10%
Secondary (BRN – BRN): 2.85 ± 10%
Thermal cut-off temp.
145°C
Outdoor Unit AER507SCL - AER509SCL - AER512SCL
Power Relay (PR)
G7L-2A-TUB
Coil rating
AC 200 – 240V, 50/60Hz
Coil resistance
Ω
(at 23°C)
21 ± 15%
Contact rating
AC 220V, 25A
Outdoor Unit AER507SC - AER509SC - AER512SC
Thermistor (Room sensor)
DTN-TKS134B
Resistance k
Ω
25°C 5.0 ± 3%
Thermistor (Coil sensor)
DTN-TKS131B
Resistance k
Ω
0°C 15.0 ± 2%
Transformer (TR)
ATR-J105
Rating Primary
AC 230V, 50 / 60 Hz
Secondary
19V, 0.526A
Capacity
10VA
Coil resistance
Ω
(at 21°C)
Primary (WHT – WHT): 205 ± 10%
Secondary (BRN – BRN): 2.0 ± 10%
Thermal cut-off temp.
150°C
Indoor Unit AWR507CL - AWR508CL - AWR509CL - AWR512CL