Subject to change · Filter and recirculating pump unit UMPC 045 Light Line · 0119 · EN
Page 13
www.argo-hytos.com
5.2
Controls
ON- / OFF switch
This switch is used to turn the unit on or off when the plug is plugged in.
Particle oil monitor
The particle monitor OPCom allows a particle measurement according to the latest standard. Thus, the level of contamination as well
as the trend of the cleanliness of fluids can be observed. The sensor is equipped with a data memory which internally stores up to
3,000 results. When the memory capacity has been reached, the last measured value is stored and the oldest measured value is
overwritten. For more detailed information read the supplementary documentation: OPCom Particle Monitor - Safety and operating
instructions.
Connection RS232
In the front panel of the UMPC 045 Light Line unit there is a serial interface via which the OPCom Particle Monitor can be read out
and configured.
Ball valve
The 3-way ball valve makes it possible to determine whether the oil cleanliness monitoring is to be performed before or after the
filter.
Fig.5: Operating elements
ON- / OFF switch
Particle monitor
Ball valve
Connection RS232