background image

TSE3-D

80287299 09/2019

Subject to change · TSE3-D_9193_1en_09/2019

More information at www.argo-hytos.com

Page 1 

Operating instructions - Electronic pressure switch

Contents

>

[...]

1.1 

Symbols used

1 Preliminary note

Instructions
Reaction, result
Designation of keys, buttons or indications
Cross-reference

Important note
Non-compliance may result in malfunction or interference

Information
Supplementary note

 › Please read this document prior to set-up of the unit. Ensure that the product is suitable for your application without any restrictions.
 › If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property can occur.
 › Check the compatibility of the product materials with the media to be measured in all applications.
 › Correct condition of the device for the operating time can only be guaranteed if the device is only used for media to which the wetted 

  materials are sufficiently resistant 

 3.1 Applications.

2 Functions and features

The responsibility whether the measurement device is suitable for the respective application lies with the operator.
The manufacturer assumes no liability for consequences of misuse by the operator. 
Improper installation and use of the devices result in a loss of the warranty claims.

1 Preliminary note  ............................................................................................................................................ 1

   1.1 Symbols used ........................................................................................................................................... 1

2 Safety instructions  ........................................................................................................................................ 1

3 Functions and features .................................................................................................................................. 2

   3.1 Applications  ............................................................................................................................................. 2

4 Function  ......................................................................................................................................................... 2

   4.1 Communication, parameter setting, evaluation  ................................................................................... 2

   4.2 Switching function  .................................................................................................................................. 2

   4.3 Analogue function  .................................................................................................................................. 3

   4.4 IO-Link  ...................................................................................................................................................... 3

5 Installation  ..................................................................................................................................................... 3

6 Electrical connection  ..................................................................................................................................... 4

7 Operating and display elements  .................................................................................................................. 4

8 Menu  .............................................................................................................................................................. 5

   8.1 Menu structure: main menu  ................................................................................................................... 5

   8.2 Explanation of the menu  ........................................................................................................................ 5

     8.2.1 Explanation of the menu level 1  ....................................................................................................... 5

     8.2.2 Explanation of the menu level 2  ....................................................................................................... 6

9 Parameter setting  ......................................................................................................................................... 6

   9.1 Parameter setting in general  ................................................................................................................. 6

   9.2 Configure display (optional)  .................................................................................................................. 8

   9.3 Set output signals  ................................................................................................................................... 8

     9.3.1 Set output functions  .......................................................................................................................... 8

     9.3.2 Define switching limits for the hysteresis function  ........................................................................ 8

     9.3.3 Define switching limits for the window function  ........................................................................... 8

     9.3.4 Scaling of the analogue value  .......................................................................................................... 8

   9.4 User settings (optional)  .......................................................................................................................... 9

     9.4.1 Set delay for the switching outputs  ................................................................................................. 9

     9.4.2 Set output logic for the switching outputs  ..................................................................................... 9

     9.4.3 Set damping for the switching signal  .............................................................................................. 9

     9.4.4 Damping for analogue output  .......................................................................................................... 9

     9.4.5 Zero-point calibration  ........................................................................................................................ 9

     9.4.6 Read min/max values for the system pressure  ................................................................................ 9

     9.4.7 Reset all parameters to factory setting  ............................................................................................ 9

     9.4.8 Set colour change of the display  ...................................................................................................... 9

     9.4.9 Graphical depiction of the colour change of the display  ..............................................................10

10 Operation  ..................................................................................................................................................11

   10.1 Read set parameters  ...........................................................................................................................11

   10.2 Self-diagnosis / error indications  .......................................................................................................11

11 Technical data and scale drawing  ............................................................................................................12

   11.1 Setting ranges  .....................................................................................................................................12

   11.2 Further technical data  .........................................................................................................................12

12 Factory setting  ..........................................................................................................................................12

Summary of Contents for TSE3-D

Page 1: ...s of the warranty claims 1 Preliminary note 1 1 1 Symbols used 1 2 Safety instructions 1 3 Functions and features 2 3 1 Applications 2 4 Function 2 4 1 Communication parameter setting evaluation 2 4 2...

Page 2: ...tem pressure It generates output signals according to the operating mode and the parameter setting It moreover provides the process data via IO Link The unit is laid out for fully bidirectional commun...

Page 3: ...o indicated System pressure above AEP2 20 20 5 mA System pressure below ASP2 4 3 8 mA Fault indication according to Namur 21 5 mA 4 4 IO Link General information This unit has an IO Link communication...

Page 4: ...onnected only by using any Listed CYJV 7 or R C CYJV2 8 cord in respect of Condition of Acceptability having suitable ratings Core colours BK black BN brown BU blue WH white OUT1 switching output or I...

Page 5: ...pressure at which OUTx switches with hysteresis setting Prerequisite OUTx setting is Hno or Hnc FHx FLx Upper lower limit value for system pressure at which OUTx switches with window setting Prerequis...

Page 6: ...ur window in the coLr parameter r cF or G cF diS Update rate and orientation of the display 9 Parameter setting During parameter setting the unit remains in the operating mode It continues to monitor...

Page 7: ...isplayed During operation Loc is briefly displayed if you try to change parameter values For unlocking Make sure that the unit is in the normal operating mode Press imultaneously for 10 s uLoc is disp...

Page 8: ...ing function Hno hysteresis function NO Hnc hysteresis function NC Fno window function NO Fnc window function NC Select OU2 and set the analogue function Hno hysteresis function NO Hnc hysteresis func...

Page 9: ...ss and hold or until is displayed Briefly press 9 4 7 Reset all parameters to factory setting Select rES Press Press and hold or until is displayed Briefly press We recommend noting down your own sett...

Page 10: ...r change display red 1 Initial value of the measuring range 2 Final value of the measuring range Representation r 12 G 12 only possible when ou2 switching output Display colour change for the paramete...

Page 11: ...Display Status LED OUT1 Status LED OUT2 Type of fault Fault warning Corrective measures none F Supply voltage too low Check correct the supply voltage SC flashes flashes flashes F Excessive current at...

Page 12: ...11 2 Further technical data Further technical data and scale drawing at www argo hytos com 12 Factory setting Factory setting User setting SP1 25 MEW rP1 23 MEW ou1 Hno ou2 I SP2 75 MEW rP2 73 MEW ASP...

Reviews: