nium body and the stainless steel AISI 316 head. 
It  is  not  recommended  to  install  the  inground 
horizontally  on  walls,  since  the  LED  head  is  not 
equipped  with  fixing  screws  and  could  easily 
come out of the flush­mounted box. If you wish to 
install  the  fixture  on  walls,  it  will  be  your  job  to 
ensure  stable  fixing,  depending  on  the  type  of 
structure on which the unit will be installed.

POWER SUPPLY

Disconnect the mains voltage from the system.
The  unit  does  not  require  an  external  power 
supply;  connect  the  power  cable  directly  to  the 
230V  AC  mains  voltage,  making  sure  that  the 
mains  voltage  and  frequency  are  compatible  with 
the  specifications  indicated  on  the  label.  Respect 
the L­N­E polarity indicated on the wiring terminals 
(colors brown = L, blue = N, yellow / green = E).
It  is  essential  that  each  unit  is  correctly  earthed 
and that the electrical installation complies with all 
the good technical and safety standards in force.
The  inground  cannot  be  powered  by  dimmer 
control  devices,  since  the  internal  power  supply 
could be damaged.

Wiring diagram to power supply

Summary of Contents for VEGA 12 LED

Page 1: ...ther directly with your fingers or indirectly by means of sharp or metal objects Make sure that cables cannot cause trip hazard Do not attempt to dismantle and modify the unit Due to the high technological level of this unit any service maintenance should be performed by specialised operators Please contact your Arena Luci dealer for any operation When assembling make sure that the cable glands ar...

Page 2: ...n the installation is complete the unit is at the same level of ground surface or floor that is the upper side of recessed box should match the finished surface A the inground box must be placed on a layer of draining pebbles with a minimum thickness of 30cm in order to make easier the flow of rain water and avoid the lift of moisture inside the box At the end of the installation it will be possib...

Page 3: ...ltage from the system The unit does not require an external power supply connect the power cable directly to the 230V AC mains voltage making sure that the mains voltage and frequency are compatible with the specifications indicated on the label Respect the L N E polarity indicated on the wiring terminals colors brown L blue N yellow green E It is essential that each unit is correctly earthed and ...

Page 4: ...2014 GPSD 2001 95 CE Warnings Disposal of Old Electrical Electronic Equipment applicable in the European Union and other European countries with separate collection systems The product shall not be treated as household waste but must be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is correctly disposed you will hel...

Reviews: