Arena Luci LC9182SZG-DIM User Manual Download Page 1

LC9182SZG-DIM

User’s manual

Single color ZigBee remote controller

Please note that as part of Arena Luci's ongoing commitment to continuous product development, specifications
are subject to change in the course of product improvement without notice. Arena Luci is not responsible for
damages resulting from improper or different use than expected.

This

instruction

manual

contains

important

information about the installation and use of the
projector.

Please

read

and

follow

these

instructions carefully.
The security of this device is guaranteed only with
the proper use of the following instructions,
therefore they must be kept carefully.
Never install the device in locations easily
accessible by people who ignore the existence of
this user's manual and safety instructions.
Disconnect the unit from any power supply before
attempting any operation in contact or inside the
unit, and when not in use.
It is essential that each device is correctly earthed
and that electrical installation conforms to all
relevant standards.
Prior to connect the unit to the mains supply,
check the output voltage fits the technical
requirements on the label.
Never let the power cord come into contact with
other cables.
Never touch the electrical contacts, either directly
with your fingers, or indirectly by means of sharp
or metal objects.
Make sure that cables cannot cause trip hazard.
Do not attempt to dismantle and modify the unit.
Due to the high technological level of this unit, any

service maintenance should be performed by
specialised operators. Please contact your Arena
Luci dealer for any operation.
Always ensure that the structure to which you are
attaching the unit is secure and is able to support
the weight of each unit.
Do not allow contact with water or any other fluids,
or metallic objects (IP 20).
Do not install the projector in areas of high
humidity. The unit is intended only for indoor
purposes.
Avoid installing the unit close to heat sources.
Allowed to be mounted directly on inflammable
surfaces.
Install the unit where it can be easily aerated.
Do not use any solvent based cleaning agents.
Use only a soft, dry anti-static cloth.
The installation of LED modules (including power
supplies) should be done according to current
technical rules and regulations. The installation
should be performed only by a qualified operator.
Avoid contact with either corrosive agents or
humidity and moisture on delicate elements:
damages from corrosion are not refunded as
component defects.

WARNINGS

Summary of Contents for LC9182SZG-DIM

Page 1: ...Never let the power cord come into contact with other cables Never touch the electrical contacts either directly with your fingers or indirectly by means of sharp or metal objects Make sure that cables cannot cause trip hazard Do not attempt to dismantle and modify the unit Due to the high technological level of this unit any service maintenance should be performed by specialised operators Please ...

Page 2: ...f remote control Touch color wheel touch to select brightness Press and hold down to increase decrease light intensity 75 brightness 100 brightness 25 brightness 50 brightness Click to turn ON OFF all groups Press and hold down to save colors Click to recall the saved colors Group numbers click to choose the group groups press and hold down to turn on off corresponding group ...

Page 3: ...ups for binding max 30 lighting devices and enables to control single color ZigBee lighting devices ZigBee Dim remote based on ZigBee 3 0 Enables to control single color lighting devices High sensitive high stable touch color wheel fast precise color control Battery powered remote with low power consumption Enables to pair ZigBee lighting devices through touchlink commissioning Supports find and b...

Page 4: ... the remote LED indicator flashes fast for 3S then flash 6 times slowly to indicate successful pairing to the device and the light connected to the device will blink twice 5 Factory Reset Manually LED indicator Step 2 Immediately short press 5 times continuously indicator flashes 3 times quickly to indicate successful reset Step 1 Press and hold down until LED indicator turns on Note All configura...

Page 5: ...as instructed indicator flashes 3 times quickly to indicate successful removing 6 Zigbee Network Pairing through Coordinator or Hub Added to a Zigbee Network LED indicator Note 1 After pairing successfully the remote information will appear on the controller or hub interface 2 No remote information will appear on the hub interface if pairing to Philips Hue Bridge Step 1 Remove the remote from prev...

Page 6: ...ghting devices ZigBee Lighting Device Step 1 Start find and bind mode on the ZigBee lighting device initiator node and enable it to find and unbind target refer to its manual LED indicator Step 2 Short press the group button that the device already bound to Step 3 Press and hold down until LED indicator turns on Step 4 Short press twice to enable the remote target node to find and unbind initiator...

Page 7: ...by a coordinator 14 How to Check Whether the Remote Belongs to a Network or not Activate the remote by clicking All On Off button indicator on then short press any other buttons except group buttons indicator blinking 3 times means the remote does not belong to any network blinking once or twice means it has already been added to a network ZigBee Lighting Device 10cm Step 1 Factory reset the remot...

Page 8: ... are required to obtain information or assistance from the dealer We invite you to transcribe them in time for any request of information or services this will result in a quick and effective operation CE RULES The device meets the essential requirements of the Directives LVD 2014 35 UE EMC 2014 30 UE RAEE 2012 19 UE RoHS 2011 65 UE Ecodesign 2009 125 CE reg UE 1194 2012 Energy label 2010 30 UE re...

Reviews: