Arena Luci LC5003 User Manual Download Page 4

4/8

LC5003

press displays red again, and so on. Also in this

case the control unit keeps track of which cell is

playing, so that if you launch the automatic

sequence or if you change the colour with the

colour wheel, each new press on memory pad will

reproduce the proper colour of the next cell.

It is possible to replace the colours in the three

memory cells, so as to quickly recall the three

colours that you most frequently use. Repeatedly

press the pad memory until you see the colour

that should be replaced; set the new colour with

one of the previously seen modes (single colour

RGBW, or colour wheel, or by automatic

sequence, but it must be paused before storage),

and then press and hold the memory pad for more

than 5 seconds; the connected lights will flash

once to indicate the correct storage of colour.

Repeat the same steps to change the colour of

the other two memory locations.

INSTALLATION AND CONNECTION

Before carrying out any operation, disconnect the

unit from any power supply.

Remove the front panel from the body of the unit,

using a screwdriver in the reference notch at the

bottom; this is essential to be able to fix the unit.

Be careful not to damage the electrical contacts of

the central connector that joins the body to the

front panel of the controller.

The LC5003 controller must be installed in a

standard flush box type 503. Lay the box in the

desired position, practicing the track into the wall

needed to house the box and corrugated pipes

that carry either the electrical power line, the

control lines to LED luminaires and the DMX

control line to the lighting system.

It is also possible to mount on the wall, in this

case the connection cables can reach the control

unit through a duct wall.

Respect the polarity of the anode-cathode LED

devices. Connect to the "+" terminal the positive

supply line of LED devices, connected to "R", "G",

"B" terminals the negative power lines of the of

RGB LED devices, connected to "W" terminal the

negative power line of white-light LED devices.

The terminal block can accept conductors of cross

section between 0.5 and 1 .5 mm

2

; for fixing

remove approximately 6-7 mm of insulation from

the wires.

The choice of power supply for the interface must

be carried out according to the total power

absorption of all LED equipments connected; once

you have this value, you can choose among the

wide range of power supplies that Arena Luci

provides.

It is recommended to leave a margin of at least

the 25% less than the driving capability of the

supply unit.

Summary of Contents for LC5003

Page 1: ...luids or metallic objects IP 20 Do not install the projector in areas of high humidity The unit is intended only for indoor purposes Always ensure that the structure to which you are attaching the unit is secure and is able to support the weight ofeach unit The installation of LED modules including power supplies should be done according to current technical rules and regulations The installation ...

Page 2: ... devices the DMX line towards intelligent devices R G B W terminal block for connection of the lines R G B of a full colour LED device and the return line of a white light LED device the three terminals labelled with are connected in parallel and are used for connection to the positive supply and for connection to the common lines of LED devices one for the full colour and one for the white The te...

Page 3: ...all the individual components and get the dark A long press on the colour pad is used to adjust the intensity of the corresponding colour At a first long press the adjustment is made from the minimum light off to the maximum starting from the current level lift the finger and a second long press will adjust the light in the opposite direction from maximum to minimum light off starting from the lev...

Page 4: ... careful not to damage the electrical contacts of the central connector that joins the body to the front panel of the controller The LC5003 controller must be installed in a standard flush box type 503 Lay the box in the desired position practicing the track into the wall needed to house the box and corrugated pipes that carry either the electrical power line the control lines to LED luminaires an...

Page 5: ...iring terminals colours brown L blue N yellow green E It is recommended that the power supply unit is connected to the mains supply via its own switch so you can turn it on and off individually The optional remote controller LC2808 works with a 3V button battery CR2025 included CONNECTION TO THE BUS DMX The connection between the control unit and the various devices must be made with 2 core screen...

Page 6: ...e graft to complete the installation Supply the control unit and connect the LED equipments to DMX bus The last effect that was running at the time of shutdown is played OPERATION Supply to the controller LC5003 In normal use you can always leave the unit powered and turn on and turn off the lights with the control pad on off Adjust the colour of the light with the colour wheel with the colour pad...

Page 7: ... off a long press restores the factory settings Play Pause key starts and pauses the internal automatic sequence Speed keys increase or decrease the execution speed of the automatic sequence Memory key plays in sequence one of the three colours stored in the three memory cells of the interface you can store a new colour by holding down the key after selecting the new colour through the front panel...

Page 8: ... treated as household waste but must be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is correctly disposed you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling The recycling of materials will help to conserve natur...