TAI60

User handbook

AC transmitter

Measurement of alternating voltage and

current

For balanced networks

True RMS values

A

R

D

E

T

E

M

T

A

C

O

1

0

2

V

2

.

x

A

0

2

/1

5

A

n

y

d

a

ta

in

th

is

d

o

c

u

m

e

n

ta

ti

o

n

m

a

y

b

e

m

o

d

if

ie

d

w

it

h

o

u

t

p

ri

o

r

n

o

ti

c

e

.

Summary of Contents for TAI60

Page 1: ...1 31 International tel 33 4 72 31 31 30 fax 33 4 72 31 31 31 www ardetem com e mail info ardetem com TAI60 User handbook AC transmitter Measurement of alternating voltage and current For balanced networks True RMS values ARDETEM TA CO102 V2 x A 02 15 Any data in this documentation may be modified without prior notice ...

Page 2: ...URATION OF THE MEASURES MENU INPUTS 8 6 CONFIGURATION OF A RELAY OUTPUT MENU OUTPUTS 10 7 CONFIGURATION OF AN ANALOG OUTPUT 12 TECHNICAL FEATURES 13 1 GENERAL FEATURES 14 2 ELECTRICAL FEATURES 14 3 POSSIBLE OUTPUTS 15 4 DIMENSIONS 16 WIRING 17 1 WIRING RECOMMENDATIONS 18 2 WIRING OF THE POWER SUPPLY 18 3 WIRING OF A SINGLE PHASE NETWORK SINGLE 19 4 WIRING OF A 3 PHASE BALANCED NETWORK WITHOUT NEUT...

Page 3: ...Page 2 U US SE E ...

Page 4: ...the digital output are the following slave number 250 speed 9600 bauds without parity 1 stop bit 2 ORGANISATION OF THE FRONT FACE IN CASE OF PROBLEM If the instrument does not light up Check the presence of power supply even for a self powered instrument If the instrument does not measure Check the presence of the measure signals Check the programming If the green LED is blinking The instrument is...

Page 5: ... SINGLE 4W BAL 3W BAL N Measured parameter 1 U13 mesh voltage U13 X 2 UL1 single voltage UL1 X X 3 IL1 line current IL1 X X X 4 F Frequency X X X SINGLE Single phase 4W BAL 3 phase balanced with neutral 3W BAL 3 phase balanced without neutral ...

Page 6: ...30VL N 600VL L 7 LIST OF THE ERRORS When the green LED on the front face is blinking the instrument is indicating an error The number of the error can be seen connecting the micro console or the PC software Err nr Types of errors Notes 0 Programme memory deleted Contact after sales 2 Wiring error Wrong wiring of the U I measure signals 4 Current caliber overstepping CC s not adapted 8 Voltage cali...

Page 7: ...Page 6 P PR RO OG GR RA AM MM MI IN NG G ...

Page 8: ...ameter s If 2 measures are being displayed the unit will appear on the side of the parameter name Otherwise it will appear under the value The measures are displayed on 4 digits the energies on 6 4 ACCESS TO THE MAIN MENU In the menus the key M is used as a back key The key menu allows entering the configuration The instrument will show its features and then open access to the main menu in reading...

Page 9: ... 600VL L 3W BAL Current range RANG I 1A 1A 5A 5A 5 3 Entering of the CT VT ratios CT VT PRI VT SEC VT 0230 Programming of the VT primary and its unit V or kV V Programming of the VT secondary without unit Do not programme a ratio but the real values PRI CT SEC CT 0005 Programming of the CT primary and its unit A or kA A Programming of the CT secondary without unit Do not programme a ratio but the ...

Page 10: ...l enforce the measure to 0 To be entered in of the caliber value 1 or 5A 100 or 330V 5 5 Processing FONCT Choice of the digital fitlering FILTER OFF Choice of the digital filtering weight NR 1 Increase the value in case of unsteady measures NR 2 NR 3 De validation of the errors DIAG OFF Allows validating or de validating the measure errors ON ...

Page 11: ...pen The hysteresis is centered around the setpoint 0 to 15 MODE SINGLE WITH 1 SETPOINT HIGH SAFETY Contact open Value of the parameter Contact closed Setpoint The hysteresis is centered around the setpoint 0 to 15 MODE WINDOW WITH 2 SETPOINTS LOW SAFETY Setpoint 1 Setpoint 2 The hysteresis are centered around the setpoint 0 to 15 Contact open Contact open Contact closed Value of the parameter MODE...

Page 12: ...e window Entering of the threshold s THRES1 THRES2 0005 Entering of the threshold in the measure unit A In the case of the mode window the 2 nd setpoint must be entered Choice of the hysteresis HYSTER 0 Choice of the hysteresis attributed to the setpoint in of the setpoint value 1 9 Choice of the time delay DELAY 0 0 S Choice of the time delay on the relay switching 0 1 S 5 S ...

Page 13: ...22mA during 1s Example output 4 20mA for Vr from 50kV to 500Kv 7 2 Configuration of the outputs procedure to be followed Choice of the measure to be transmitted MEAS O U13 Choose the measure to be transmitted IL1 Choice of the output range OUT RA 4 20mA Choice of the output range in current 0 20mA Positive scale only in the case of an instrument with the option 2A Down scale DOWN S 0000 Enter the ...

Page 14: ...Page 13 T TE EC CH HN NI IC CA AL L F FE EA AT TU UR RE ES S ...

Page 15: ...cy rating In digital output Cl 0 2 voltage current Measure cycle 40 ms for all network types Measuring method Fast simultaneous sampling of the voltage and the current Digital calculation on 32 bits Measurement of disturbed signals pass band 6 4kHz Digital filtering Various levels on choice by programming TEST AND OPERATING CONDITIONS Reference T 23 C Operating T 10 C to 55 C others on request IEC...

Page 16: ...points 0 to 100 of the measure range programmable Switching hysteresis 0 to 15 of the setpoint programmable Time delay 0 to 15s programmable Analog output option A Galvanic partition Inputs 2kV RS485 1kV Output signal programmable 0 20mA or 4 20mA Scale setting 0 to 100 of the measure range programmable Admissible load up to 600 20mA Resolution 24000 points Accuracy 0 2 of the full scale on 0 20mA...

Page 17: ...Page 16 4 DIMENSIONS May be modified any time for technical reasons 75 5 120 127 µConsole 102 5 DIN rail 22 5 13 5 26 5 80 ...

Page 18: ...Page 17 W WI IR RI IN NG G ...

Page 19: ...ay outputs Use for all the outputs of the instrument shielded cables connected to the GND on both ends In order to avoid any influence of the current take up on the voltage measure connect the CT s before the VT s 2 WIRING OF THE POWER SUPPLY Load Network S1 µConsole Power supply Measure inputs Connector of the relay outputs Configuration label A3 A2 A1 E4 E3 E2 E1 S1 S2 S3 S4 S5 S6 S7 S8 N1 N2 No...

Page 20: ... PHASE BALANCED NETWORK WITH NEUTRAL 4W BAL without VT without CT Umax 330V Imax 5A with VT with CT without VT without CT Umax 600V L L Imax 5A with VT with CT without VT without CT Umax 330V L N Imax 5A with VT with CT Respect the correct connection The secondaries S2 of the CT s must be set to the earth Load Load Load Load Load Load ...

Page 21: ...g Page 20 6 WIRING OF THE RELAY OUTPUTS 7 WIRING OF THE ANALOG OUTPUTS RELAY 1 RELAY 2 Pot free contact 5A 250V Pot free contact 5A 250V S5 S6 S7 S8 I Lr 600 20 mA S1 S2 Current outputs S3 S4 Lr 600 20 mA I ...