EN
29
With working time limitation function: End users can set up the running
procedure within a week(7days)
With black bulb sensor: During a certain period of time, the temperature
of the sensor will be induced to a sudden drop in temperature (for example,
the temperature will drop by 3 degrees within 1min), and the product will be
turned on automatically.
USER MAINTENANCE:
The heater may be wiped-down with a soft damp cloth. Do not use abrasive
detergents to clean the unit. In marine environments, the unit may be gently
sprayed clean with clean water with the POWER TURNED OFF and completely
cool. After cleaning, it is advisable to warm the heater for 10 – 20 minutes to dry
the unit and prevent staining.
The lamp used in this series heaters is Ultra long life (10,000 hours). Changing the
lamp should only be carried out by suitably qualified personnel using the instruc-
tions available on Herschel’s website.
TROUBLESHOOTING:
E1 Error on Display:
Control unit overheat. Check installation
clearances.
Let heater cool for 15 minutes and restart heater.
L1,2,3,4 shows in display, but no heat: Bulb is damaged. Arrange for replacement bulb
with local Dealer.
RECYCLING
At the end of the electrical products useful life it should not be disposed of with
household waste.
Please recycle where facilities exist. Check with your Local Authority or retailer for
recycling advice in your country.