WATER HEATING COIL (MODEL SHW4) 

 
ARDENT ENERGY heating units are designed to heat your do-
mestic hot water during the heating season. 
 
The HF85R can accept one or two coils (1 per side). The coil 
replaces all but one of the firebrick on the side located. 
 

Procedure: 
 
NOTE:

  Ensure installation complies with local plumbing codes. 

 

1.       Remove both side shrouds by unscrewing the 

screws at back. 

2.       Remove rear heat shield and punch out the 2 

knockouts on the side desired. Knock outs are 
tight, out of necessity. A sharp blow with a heavy 
hammer will be required. 

3.       Loosen cross draft angle nuts on side of unit. (2 

each side located on outside of firebox). 

4.       Remove brick from that side. 
5.       Punch out 2 knockouts at back of stove. Reach in 

through punched out holes with a bar extension 
and punch out knockouts in primary heat ex-
changer. (see Fig 5.) 

6.       Position water coil in stove, replace brick and 

tighten cross draft angle nuts on side of heater to 
hold coil in place. 

7.       Install mineral wool gasket and plate on outside 

and screw tight. 

8.       Replace shrouds and heat shield. 

 

TANK CONNECTION 

 
It is recommended that the ‘2 tank” system be used. The first 
tank or “Range Boiler” must remain un-insulated to dissipate any 
excess heat generated by the hot water coil. 
 
Connection of piping to Range Boiler must be strictly followed as 
shown in the Diagram. The 2 shut—off valves must be no smaller 
than 3/4 inch GATE valves. Make certain that the PRV (Watts 3L) 
and P&TRV (Watts 100XL) are installed in their respective loca-
tions and not vice versa. Maximum pressure setting is 150 psi. 
Do not use less than 3/4 inch diameter standard pipe between 
range boiler and heater, orientation of pipe must be slightly uphill 
from the coil outlet to the upper connection at the tank, otherwise 
vapor lock will occur and water will not circulate. Minimum range 
Boiler recommended is 30 Imperial gallon capacity. 

FIG. 6 

REPLACEMENT PARTS LIST

 

ITEM  QTY  DESCRIPTION 

PART # 

Scandinavian baffle 8 x 18 5/8 

AAP016 

Bypass damper 

A237W 

26” 

#10 Steel ball chain 

R6110 

Detachable pendant 6P 

R6121 

Flame deflector 

A540 

Down draft baffle 

A542 

Cross draft angle 

A543W 

Draft control 

A913 

Primary air heat exchanger 

A321W 

10 

19 

Firebrick 1 1/4 x 4 1/2 x 9 

R7101 

11 

Door sill 3 x 16 1/8 

AAP059 

12 

80” 

Gasket 5/8 round regular black 

R7005 

13 

Door liner 

A086 

14 

Door 

A356W 

15 

Door knob 1 7/8 OD 1/2 ID 

R6020 

16 

Door closer 

A759W 

17 

Draft/bypass handle 5/16 

R6005 

18 

Bypass bar 

A334 

19 

Draft control rod 

A324W 

20 

Bypass lever 

A239W 

21 

Smoke shield 

A079W 

22 

Draft control gasket 

A989 

Summary of Contents for HF85R

Page 1: ...Model HF85R SOLID FUEL SPACE HEATER Box 3637 Smithers BC V0J 2N0 INSTALLATION AND OPERATION INSTRUCTION MANUAL PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Operation Maintenance Installation ...

Page 2: ...r should be included with your order to assure prompt and accurate service We congratulate you on your choice of the ARDENT ENERGY heating system and may your home fires keep burning Yours truly ARDENT ENERGY Inc J G Hans Duerichen P Eng President June 2001 ver 3 TABLE OF CONTENTS SAFETY INSTRUCTIONS PAGE 3 GENERAL SPECIFICATIONS PAGE 3 OPERATION INSTRUCTIONS PAGE 4 Fuel PAGE 4 The bypass damper P...

Page 3: ... damper and turn down the draft damper com pletely On thermostat models turn down thermo stat If chimney fire does not die down keep a watch on fire and prepare to vacate the house If needed call the fire department NOTE 1 Establish a routine for the storage of fuel care of wood burner and firing technique Be aware that dur ing mild weather and low heater temperatures more creosote is deposited an...

Page 4: ...errun then the temperature will stabilize RELOADING 1 Have wood on hand to load firebox 2 Open bypass lever for 30 seconds 3 Open the door SLOWLY Allow the chimney to draw off smoke 4 Load wood 5 Close door and push bypass lever in DO NOT OVER FIRE UNIT BY LEAVING DOOR OPEN EX CEPT TO LIGHT AND TO CHECK FIRE Operation with door ajar voids warranty NOTE Cleanest burning conditions occur when the fu...

Page 5: ...dicate the center of the chimney 4 Check that the intended location will not interfere with ceil ing joists or rafters before proceeding further 5 Install chimney according to chimney manufacturer s in structions Read section on Chimney and see Diagram 2 Chimney must be a 8 diameter listed chimney suitable for wood burning appliances If an existing masonry chimney is to be used read section under ...

Page 6: ...he above specifications CHIMNEY TERMINATION Chimneys are required to extend at least 915 mm 3 above the highest point where they pass through the roof of the building and at least 610 mm 2 higher than any portion within ten feet In some cases the chimney must be higher than minimum for enough draft due to unfavorable geometry of the surroundings INSTALLATION OF OPTIONS WALL THERMOSTAT KIT MODEL HC...

Page 7: ...issipate any excess heat generated by the hot water coil Connection of piping to Range Boiler must be strictly followed as shown in the Diagram The 2 shut off valves must be no smaller than 3 4 inch GATE valves Make certain that the PRV Watts 3L and P TRV Watts 100XL are installed in their respective loca tions and not vice versa Maximum pressure setting is 150 psi Do not use less than 3 4 inch di...

Page 8: ...RE FOR EASY REFERENCE WHEN ORDERING REPLACEMENT PARTS MODEL ____________________________________________ SERIAL I ___________________________________________ DATE OF INSTALLATION _______________________________ 16 11 10 21 6 1 3 22 8 20 5 12 2 15 13 14 7 4 9 ...

Page 9: ...be replaced or repaired upon return of the defective part to an au thorized Ardent Energy Ltd dealer 2 Any space heater or part thereof that is replaced or serviced during the three year warranty period will be warranted under the terms of that particular limited warranty for a period not exceeding the re maining term of the original limited warranty or six months whichever is longer 3 This warran...

Reviews: