Ardent Energy HF85R Installation And Operation Instruction Manual Download Page 6

Model HF85R                                                                                                        6 

FLOOR 
SHIELD 

LIP INSIDE 
FLUE COLLAR 

CEILING SHIELD 

TRIM COLLAR 

RAIN CAP 

STORM 
COLLAR 

FLASHING 

CAUTION: 

UNDER NO CIRCUMSTANCES MUST ANY TYPE 

OF DAMPER OR RESTRICTION BE INSTALLED IN THE CHIM-
NEY OR CONNECTING STOVE PIPE. 

 
CHIMNEY 

 
Chimney size:  178 mm (8”) diameter or 150 mm x 250 mm (6” x 
10”) maximum inside measure masonry chimney. 
 
Metal chimneys must be of a type suitable for wood burning ap-
pliances and masonry chimneys must be lined with an approved 
liner. 
 
ARDENT ENERGY heating units burn very efficiently, resulting in  
lower than usual flue gas temperatures. For this reason, 
outside installation of the chimney is not recommended. Due to 
the fact that it will dissipate more heat, an outside chimney will 
cause more problems with low draft and excessive creosote ac-
cumulation. 
 
On initial operation of the heating unit a draft reading should be 
taken. (Contact your local ARDENT ENERGY dealer for further 
information on measuring draft). The draft should measure .06 
water column with the unit at normal operating temperature. If 
this reading has to be induced by a roaring fire, it is an indication 
that draft is inadequate. If the draft is more than .06 a draft  

regulator should be fitted to the connector pipe. If the draft is less 
than .06 appropriate action should be taken to improve the draft. 
 
eg.       a) insulate chimney 

b) move unit to eliminate horizontal section 
c) add to top of chimney 

 
If an existing chimney is to be used, it must be inspected carefully 
for soundness and to assure that it meets the above specifications.  
 

CHIMNEY TERMINATION 

 
Chimneys are required to extend at least 915 mm (3’) above the 
highest point where they pass through the roof of the building and 
at least 610 mm (2’) higher than any portion within ten feet. In 
some cases the chimney must be higher than minimum for enough 
draft due to unfavorable geometry of the surroundings. 

 

INSTALLATION OF OPTIONS 

 
WALL THERMOSTAT KIT (MODEL HC2) 

 
The control system consists of an electric damper control unit and 
a wall thermostat. 

 

INSTALLATION 

 
1.     Remove the 32 mm (1 1/4”) knockout at top left of rear heat 

shield. Insert arm through hole and screw the damper control 
unit into pre-drilled holes. 

2.     Remove left hand side shroud by unscrewing 2 screws at 

back. 

3.     Attach one end of ball chain to damper control arm. 
4.     Attach the remaining end through hole in air intake assembly. 

(There should be a slight slack in the chain.) 

5.     Locate thermostat some distance from heater 3M - 6M (10’ - 

20’) but not in another room unless direct venting is provided 
for hot air. 

6.     The thermostat should be set on an interior wall. Follow manu-

facturer’s instructions. 

7.     The heat anticipator setting should be 0.4 amps. 
8.     Check chain length by shutting off the manual control and 

setting the thermostat above room temperature. The draft 
damper should open to maximum. 

9.     Set thermostat below room temperature; the draft damper 

should close completely. Adjust chain length if required.

 

HEAT  
DEFLECTOR 

THERMOSTAT 
CONTROL 

HEAT EX-
CHANGE FINS 

HEAT SHIELD 
MOUNTING 
SCREW 

AIR INLET 
ASSEMBLY 

WATER COIL 
KNOCKOUT 

MANUAL 
CONTROL 

FIG. 5 

WALL THERMO-
STAT CONTROL 

CHECK REAR 
CLEARANCE 

8” DIA 24 GA 
STEEL  
CHIMNEY  
CONNECTOR

 

8” DIA. LISTED 
CHIMNEY 
SUITABLE FOR 
WOODBURNING 
APPLIANCES

 

915 mm (36”) 
MINIMUM 

FIG. 4 

Summary of Contents for HF85R

Page 1: ...Model HF85R SOLID FUEL SPACE HEATER Box 3637 Smithers BC V0J 2N0 INSTALLATION AND OPERATION INSTRUCTION MANUAL PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Operation Maintenance Installation ...

Page 2: ...r should be included with your order to assure prompt and accurate service We congratulate you on your choice of the ARDENT ENERGY heating system and may your home fires keep burning Yours truly ARDENT ENERGY Inc J G Hans Duerichen P Eng President June 2001 ver 3 TABLE OF CONTENTS SAFETY INSTRUCTIONS PAGE 3 GENERAL SPECIFICATIONS PAGE 3 OPERATION INSTRUCTIONS PAGE 4 Fuel PAGE 4 The bypass damper P...

Page 3: ... damper and turn down the draft damper com pletely On thermostat models turn down thermo stat If chimney fire does not die down keep a watch on fire and prepare to vacate the house If needed call the fire department NOTE 1 Establish a routine for the storage of fuel care of wood burner and firing technique Be aware that dur ing mild weather and low heater temperatures more creosote is deposited an...

Page 4: ...errun then the temperature will stabilize RELOADING 1 Have wood on hand to load firebox 2 Open bypass lever for 30 seconds 3 Open the door SLOWLY Allow the chimney to draw off smoke 4 Load wood 5 Close door and push bypass lever in DO NOT OVER FIRE UNIT BY LEAVING DOOR OPEN EX CEPT TO LIGHT AND TO CHECK FIRE Operation with door ajar voids warranty NOTE Cleanest burning conditions occur when the fu...

Page 5: ...dicate the center of the chimney 4 Check that the intended location will not interfere with ceil ing joists or rafters before proceeding further 5 Install chimney according to chimney manufacturer s in structions Read section on Chimney and see Diagram 2 Chimney must be a 8 diameter listed chimney suitable for wood burning appliances If an existing masonry chimney is to be used read section under ...

Page 6: ...he above specifications CHIMNEY TERMINATION Chimneys are required to extend at least 915 mm 3 above the highest point where they pass through the roof of the building and at least 610 mm 2 higher than any portion within ten feet In some cases the chimney must be higher than minimum for enough draft due to unfavorable geometry of the surroundings INSTALLATION OF OPTIONS WALL THERMOSTAT KIT MODEL HC...

Page 7: ...issipate any excess heat generated by the hot water coil Connection of piping to Range Boiler must be strictly followed as shown in the Diagram The 2 shut off valves must be no smaller than 3 4 inch GATE valves Make certain that the PRV Watts 3L and P TRV Watts 100XL are installed in their respective loca tions and not vice versa Maximum pressure setting is 150 psi Do not use less than 3 4 inch di...

Page 8: ...RE FOR EASY REFERENCE WHEN ORDERING REPLACEMENT PARTS MODEL ____________________________________________ SERIAL I ___________________________________________ DATE OF INSTALLATION _______________________________ 16 11 10 21 6 1 3 22 8 20 5 12 2 15 13 14 7 4 9 ...

Page 9: ...be replaced or repaired upon return of the defective part to an au thorized Ardent Energy Ltd dealer 2 Any space heater or part thereof that is replaced or serviced during the three year warranty period will be warranted under the terms of that particular limited warranty for a period not exceeding the re maining term of the original limited warranty or six months whichever is longer 3 This warran...

Reviews: