the control panel based on operation manual inside of cabinet. 
 

CAUTION 

Setting the temperature control to the coldest setting may cause the evaporator coil to freeze 
and ice up. This will eventually result in a warmer cabinet temperature. 

 

LOADING PRODUCT 

Shelves have been factory-installed for your convenience. Before loading shelves, please be 
sure that all shelf clips are completely fastened in their correct locations. It is important that all 
shelves rest completely level before stocking your cabinet with product. 
In order to maintain correct air flow inside the unit, please be sure to leave 50 mm to 100 mm 
of space between the back wall and stored product. Blocking the evaporator fans will result in a 
warmer cabinet temperature, and ultimately compressor failure. 

 

 

 

DEFROST SYSTEMS 

Refrigerator coils are kept below the freezing point (0 C). During compressor down-time, the 
evaporator fan continues to circulate air through the evaporator coil. This air circulation raises 
the coil temperature above the freezing point, melting any accumulated frost. Run-off water is 
drained into the evaporator pan and evaporated.   
 
PLEASE NOTE: Excessive door openings should be avoided in order to maintain cabinet 
temperature and to eliminate the possibility of coil freeze-up. 

 

 
 
 
 

SAFETY / WARNING 

 

Please pay close attention to the safety notices in this section. 
Disregarding these notices may lead to serious injury and/or damage to the 
unit. 

 
 

ATTENTION 

 To minimize shock and fire hazards, be sure not to overload outlet. Please designate one 

outlet for your unit. 

 Do not use extension cords. 

 Do not put your hands under the unit when the unit is required to be moved. 

 When the unit is not in use for a long period of time, please unplug the unit from the outlet. 

Summary of Contents for HEF546

Page 1: ...stallation Operation Maintenance Manual Upright Refrigerator Freezer HEF546 HEF547 Upright Bottle Coolers HC gas R600 R290 used For warranty Tel 03701 647647 Email address service lockhartcatering co...

Page 2: ...r electric shock Do not disassemble repair or alter the appliance It may cause fire or abnormal operations Any repair work should be carried by a qualified service agent Do not use store electrical ap...

Page 3: ...t and moisture generating equipment high ambient temperatures will cause the compressor to overwork leading to higher energy bills and gradual breakdown of the unit malfunction due to high ambient tem...

Page 4: ...re DEFROST SYSTEMS Refrigerator coils are kept below the freezing point 0 C During compressor down time the evaporator fan continues to circulate air through the evaporator coil This air circulation r...

Page 5: ...g the unit PROPER GROUNDING REQUIRED To minimize shock and fire hazards make sure that the unit is properly grounded PROHIBITION Do not attempt to remove or repair any component unless instructed by f...

Page 6: ...the fan motor to prevent moisture damage CLEANING THE INTERIOR OF UNIT When cleaning the cabinet interior use a solvent of warm water and mild soap Do not use steel wool caustic soap abrasive cleaner...

Page 7: ...Ensure doors are closed when not in use Avoid opening doors for long periods of time Ensure gaskets are snapped in completely Remove gasket and wash with soap and water Check condition of gasket and r...

Page 8: ...ecialist companies who remove or recycle all glasses metal and plastic components Consult your local waste collection authority regarding disposal of your appliance Local authorities are not obliged t...

Page 9: ...specification set by international independent and federal authorities Products have been approved to carry the following symbol...

Reviews: