Install the unit on strong and leveled surfaces
-unit may make unpleasant noises if surface is uneven
-unit may malfunction if surface is uneven
■
Install the unit in an indoor, well-ventilated area
-unit performs more efficiently in a well-ventilated area
-for best performance, please maintain clearance of 30 mm on the back of the unit
-outdoor use may cause decreased efficiency and damage to the unit
■
Avoid installation in a high humidity and/or dusty area
-humidity could cause unit to rust and decrease efficiency of the unit
-dust collected on condenser coil will cause unit to malfunction. Clean the condenser at least
once a month with a brush or clean cloth
-malfunction due to dirty condenser will void warranty
■
Select a location away from heat and moisture-generating equipment
-high ambient temperatures will cause the compressor to overwork, leading to higher energy
bills and gradual breakdown of the unit
-malfunction due to high ambient temperature will void warranty
ELECTRICAL
Please ensure that the required voltage of the compressor is being always supplied. Low or
high voltage can detrimentally affect the refrigeration unit.
All units should be plugged into a grounded and properly sized electrical outlet with
appropriate overcurrent protection. Please refer to the electrical requirements on the
nameplate of the unit. Please make sure that your unit has its own dedicated outlet. Do not use
an extension cord.
TEMPERATURE CONTROLS
The temperature controls are factory-set to maintain an average temperature of 0 C in
refrigerators. To maintain a different temperature, simply adjust the thermostat is located at
All electrical work must be carried out by suitably qualified
persons