ARCTIC WIND 2AD22A Owner'S Manual Download Page 17

16

TROUBLESHOOTING TIPS

PROBLEM

WHAT TO CHECK

Unit does not start

•  Make sure the dehumidifier s plug is pushed completely into the outlet.
•  Check the house fuse/circuit breaker box.
•  Dehumidifier has reached its preset level or bucket is full.
•  Water bucket is not in the proper position.

Dehumidifier does not dry 

the air as it should

•  Did not allow enough time to remove the moisture.
•  Make sure there are no curtains, blinds or furniture blocking the front or 

back of the dehumidifier.

•  The humidity control may not be set low enough.
•  Check that all doors, windows and other openings are securely closed.
•  Room temperature is too low , below 5 oC(41o F).
•  There is a kerosene heater or something giving off water vapor in the room.

The unit makes a loud 

noise when operating

•  The air filter is clogged.
•  The unit is tilted instead of upright as it should be.
•  The floor surface is not level.

Frost appears on the coils

•  This is normal. The dehumidifier has Auto defrost feature.

Water on floor

•  Hose to connector or hose connection may be loose.
•  Intend to use the bucket to collect water, but the back drain plug is removed.

The pump operation on 

light blinks at 1Hz

•  Clean the filter of the pump.
•  Check the pump hose does not link or block.
•  Empty the water of the bucket.

ES - Tube  

Temperature sensor  

of the evaporator error

•  Unplug the unit and plug it back in. If error repeats, call for service.

AS - Humidity sensor error

•  Unplug the unit and plug it back in. If error repeats, call for service.

P2 - Bucket is full or bucket 

is not in right position

•  Empty the bucket and replace it in the right position

Eb - Bucket is removed or 

not in right position

•  Replace the bucket in the right position.

Before calling for service, review the chart below.

The design and specifications are subject to change without prior notice. Consult with the sales agency or 

manufacturer for details. Any updates to the manual will be uploaded to the service website, please check  

for the latest version.

Summary of Contents for 2AD22A

Page 1: ...DEHUMIDIFER MODEL 2AD22A 2AD35A 2AD50A 2ADP50A OWNER S MANUAL...

Page 2: ...IMPORTANT Thank you for your purchase Please read this manual carefully before operating Make sure to save this manual for future reference...

Page 3: ...D22A 2AD35A 2AD50A 2ADP50A SAFETY INFORMATION 3 IDENTIFICATION OF PARTS 6 POSITIONING THE UNIT 7 OPERATING INSTRUCTIONS 8 OTHER FEATURES 11 REMOVING THE COLLECTED WATER 12 CARE AND MAINTENANCE 15 PREP...

Page 4: ...njury fire or electrical shock Warning This symbol shows that this appliance uses a flammable refrigerant If a refrigerant leak occurs and is exposed to an external ignition source there is a risk of...

Page 5: ...nto the unit Place the unit on a level sturdy section of the floor Do not cover the intake or exhaust openings Never insert your finger or other foreign objects into grills or openings Take special ca...

Page 6: ...ll only be performed an authorized service provider recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the...

Page 7: ...subject to change without prior notice Consult with the customer service for details The most up to date versions of the manual can be found on the service website Please check for the latest version...

Page 8: ...strong enough to support the unit with a full bucket of water For good air circulation allow at least 8 inches of air space on all sides of the unit and a minimum of 16 inches of air space at the air...

Page 9: ...e the Wireless connection mode some models only press the filter button for 3 seconds when the unit is powered on or powered off The LED DISPLAY will display AP to indicate you have entered the wirele...

Page 10: ...0 to 24 hrs Press the TIMER button the timer Off or On indicator light illuminates This indicates the auto stop start program is initiated Press or hold the or button to change the desired stop start...

Page 11: ...pump operation Refer to the next pages for removing the bucket and discarding the collected water Do not use this operation when the outdoor temperature is at or below 32 F 0 C LED Display __________...

Page 12: ...the frost disappears During this operation the Auto Defrost indicator light will be illuminated Auto Shut Off ___________________________ The dehumidifier shuts off when the bucket is full or when the...

Page 13: ...difier to operate The machine will re start when the bucket is returned to its correct position NOTE When you remove the bucket do not touch any parts inside the unit Doing so may damage the product B...

Page 14: ...d flow of water towards the outlet Select the desired dehumidifier setting humidity level and fan speed Pump draining on some models Water can be automatically emptied into a floor drain or a suitable...

Page 15: ...nit If the error repeats call for service Empty the bucket once a week when using the pump drain feature When the pump drain feature is not being used remove the pump drain hose from the outlet Press...

Page 16: ...ntegrated with the back panel of the unit and is not a separate item Remove the filter every two weeks based on normal operating conditions To remove the filter pull filter outwards See Fig 14 Wash th...

Page 17: ...Frost appears on the coils This is normal The dehumidifier has Auto defrost feature Water on floor Hose to connector or hose connection may be loose Intend to use the bucket to collect water but the...

Page 18: ......

Page 19: ......

Page 20: ...855 663 9463 www arcticwindac com 5401 Dansher Road Countryside IL 60625 Printed in China 1220_M559...

Reviews: