Maximum wall thickness: 12" or 10"
1. Prepare the wall in frame construction (including
brick and stucco veneer). Working from inside the
room, find the wall stud closest to the centre of the
area where the air conditioner will be installed (by
sounding the wall, or by magnetically finding nails).
2. Cut or knock out a hole on each side of the center
stud.
3. Measure between the inside edges of every other
stud as shown in Fig. 1.
4. Build a wooden frame with the INSIDE dimensions
of your model listed above (measure twice). Frame
depth should be the same as wall thickness. Fill in
the space from the opening to the studs with wood
spacers, as shown.
5. Nail the frame to the spacers with the front flush
with the drywall.
Fig.2
Installation Instructions
Through-the-Wall Installtaion
I
All the parts needed for through-the-wall-
installation are provided, except for the wood frame,
shims, and 10 wood screws (at least #10-1" long).
21
NOTE: Consult the local building codes prior to
installation or a qualified carpenter.
Select Wall Location
1. Does not support major structural loads such as
the frame construction at window ends and under
truss-bearing points.
2. Does not have plumbing or wiring inside.
3. Is near existing electrical outlets or where another
outlet can be installed.
4. Is facing and not blocking the area to be cooled.
5. Allows free airflow from the rear sides and from
the end (outside) of the installed air conditioner.
Prepare the wall
(
)
Inside
frame
height