![Arctic Cat 350 2011 Service Manual Download Page 130](http://html.mh-extra.com/html/arctic-cat/350-2011/350-2011_service-manual_2965305130.webp)
4-17
4
INSTALLING
1. Mark the new fuel pump with a reference mark in
the same location as the removed pump; then place
the new gasket on the pump.
2. Remove the material covering the fuel pump open-
ing; then carefully guide the fuel pump into posi-
tion taking care not to damage the float or float
lever.
KX190
3. Rotate the fuel pump until the match marks align;
then install the mounting screws and tighten
securely using a crisscross pattern.
NOTE: It is important to install the fuel pump with
the correct orientation to ensure adequate float
lever clearance.
4. Connect the wires and fuel hose; then connect the
negative battery cable and turn the ignition switch
to the ON position. Note that the fuel pump runs
momentarily and the fuel gauge indicates the
proper fuel level.
5. With the transmission in neutral and brake lever
lock engaged, start the engine and check for nor-
mal operation. Check for any fuel leaks.
6. Install the gas tank cover, side heat shields, and
seat making sure the seat locks securely.
Troubleshooting (350)
Problem: Starting impaired
Condition
Remedy
1.
Starter jet
obstructed
2.
Starter jet passage
obstructed
3.
Carburetor
leaking air
4.
Gas
contaminated
1. Clean jet
2. Clean passage
3. Replace gasket
4. Drain gas tank and fill with clean gas
Problem: Idling or low speed impaired
Condition
Remedy
1.
Slow jet
obstructed - loose
2.
Slow jet outlet
obstructed
3.
Low speed fuel screw setting
incorrect
4.
Float height
incorrect
5.
TPS
out of adjustment
1. Clean - tighten jet
2. Clean outlet
3. Adjust screw
4. Adjust float height
5. Adjust TPS
Problem: Medium or high speed impaired
Condition
Remedy
1.
High RPM “cut out”
against RPM limiter
2.
Main jet
obstructed
3.
Needle jet
obstructed
4.
Vacuum piston
not operating properly
5.
Filter
obstructed
6.
Float height
incorrect
1. Shift into higher gear - decrease RPM speed
2. Clean main jet
3. Clean needle jet
4. Check piston operation
5. Clean filter
6. Adjust float height
Problem: Overflow and fuel level fluctuations
Condition
Remedy
1.
Float valve
worn - damaged
2.
Float valve spring
broken
3.
Float
not working properly
4.
Float valve
dirty
5.
Float height
too high - too low
1. Replace valve
2. Replace spring
3. Adjust float height - replace float
4. Clean valve
5. Adjust float height
Section